background image

9.

11.

10.

1. 

Disconnect Inlet Hose from Dirty Water Reservoir and  

 

fill reservoir with 3- 4 liters of water.

 

2.  

Fill the rest of Dirty Water Reservoir with as much air  

 

as possible. Roll Closure Strap 4+ times to seal.

3.  

Reconnect Inlet Hose to Dirty Water Reservoir.

4.  

Lay hose system on ground in front of you so that it’s  

 

easy to view the entire Inlet and Outlet hose. 

5. 

Flip Dirty Water Reservoir so that its hose port is    

 down.

6. 

Holding the rolled Closure Strap, kneel on Dirty Water  

 

Reservoir and force water through Inlet Hose. Ensure  

 

no air enters. 

7. 

Open Purge Valve to purge all air bubbles from  

 

 

Purifier Cartridge. 

Then close it.

8. 

Open Shutoff Clamp while continuing to kneel on    

 

reservoir. Fill Outlet Hose with water.

9. 

Flip Dirty Water Reservoir over so that its hose port is  

 

facing up.

10. 

Kneel on reservoir and force ONLY air through Inlet   

 

Hose all the way through to the Purifier Cartridge.

 

NOTE: Your goal is to force air against the fully  

 

 

wetted hollow fibers inside the cartridge. If a fiber is  

 

damaged, air will escape, revealing a steady stream  

 

of bubbles in the Outlet Hose. 

11. 

If a steady stream of bubbles appears in the Outlet   

 

Hose as you force the air through, we recommend    

 

repeating this test twice to ensure accuracy. If you see  

 

bubbles each time, your purifier is NOT SAFE.  

 

 

Discontinue use and replace. 

These instructions are available in other languages at www.

msrgear.com/guardian-gravity-purifier

The filter media can be damaged if dropped, or if frozen 

after use. If either of these has happened, perform an 

integrity check.  

5. Purifier Integrity Test