background image

To eliminate the growth of bacteria or mold, which can 

slow flow rates, always disinfect the purifier 

BEFORE

      

long-term storage (15+ consecutive days).  

4. DISINFECT PURIFIER

5.

3.

1— 2

7.

7.

8.

6.

5.

1. 

Disconnect Inlet Hose from Dirty Water Reservoir. 

 

2. 

Rinse reservoir with tap water to remove any debris   

 

from Prefilter Screen. 

3. 

Ensure Shutoff Clamp and Purge Valve are closed. 

4. 

Fill Dirty Water Reservoir with at least 3 liters of warm  

 

tap water and reattach Inlet Hose. 

5. 

Open both Purge Valve and Shutoff Clamp. Filter    

 

water through system. Close Purge Valve and 

 

Shutoff Clamp.  

6. 

Refill reservoir with 2 liters of clean water and add 5  

 

mL (≈ 1 tsp) of household bleach free of dyes or  

 

 

perfumes (5.25%-8% chlorine concentration). 

7. 

Place Bottle Adapter in sink. Hold or hang reservoir   

 

above sink. 

8. 

Open Purge Valve and Shutoff Clamp and filter ½ of  

 

bleach solution through system into sink.

9. 

Close valve and clamp. (Purifier Cartridge should now  

 

be filled with bleach.)

10. 

Wait 30 minutes.

11. 

Run second ½ of bleach solution through cartridge,   

 but 

STOP

 just before Dirty Water Reservoir is emptied  

 

(so that bleach remains in cartridge).

12. 

Wait another 30 minutes.

13. 

Drain all solution from system.

14. 

Air or towel dry system parts completely, leaving all   

 

hoses attached. (NOTE: The bleach in the cartridge   

 

will prevent the growth of harmful microorganisms and  

 

biofilm inside.)

15. 

Pack and store Guardian Gravity system in storage   

 sack.

After long-term storage, before using the purifier, filter 2-3 

liters of water through the system to rinse it. 

 

DO NOT

 disassemble and dry out the Purifier Cartridge before storing 

it. If the cartridge’s internal fibers dry out, they will no longer pass water; the cartridge must stay 

wet inside.

WARNING

 

DO NOT

 use more bleach than recommended, as doing so can damage 

the fibers. 

WARNING

 

Disinfect the purifier thoroughly before long-term storage to prevent the 

growth of mold, mildew and bacteria. Never use a dishwasher or microwave to disinfect parts because 

the high heat will damage or melt them.

WARNING