2016 Premium MSpa Service Manual
Visit us at: www.the-mspa.com
- 18 -
15. Take out the original bubble generator from the
control box and assemble the new one in reverse order
4.6 How to Replace the Check Valve
1. Remove the air pipe
2. Turn the control box inside the spa pool upside down
3. Unscrew the screws that fix check valve in place.
4. Take out the original check valve and put the seal ring
in good condition.
5. Assemble the new check valve by screws.
6.screw the nut of spa pool
4.7 How to Replace the Transformer