17
Celsius/Fahrenheit Toggle Button:
The temperature can be displayed in either Celsisu
or Fahrenheit. The system's default is Celsius.
Ozonator Button:
Activate the Ozone. The Ozone icon shows when the Ozone function is
activated. For bathers' safety concern, the ozonator cannot be operated at the same time
when the Bubbling function is on. The Ozonator will be off automatically after opearting for 2
hours. Ozone output is 50-80mg/Hr.
NOTE: Please do not soak in the spa when the Ozone is on. The Ozonator will not work
when the spa has no water or when the Bubble Button is on.
IMPORTANT
:
The following conditions will lead to slow water heating
=# # @[\]@[
^ _"]`]{#|}`%#
= _
= _ _
LED READING
CAUSE
SOLUTION
E0
E1
E2
E3
Flashing E3
E4
Water temperature is lower than zero degree
or too high
Water pressure switch failure
Filter failure
Water level is not reached the minimum water line
Detecting function failure
No water in the spa tub
Heating failure
System failure
Heating failure
Please contact the MSpa Service Center.
Add more water to reach the minimum line
Please contact the MSpa Service Center.
Please contact the MSpa Service Center.
Add more water to the minimum line.
System self check
Step 1: Fill water to water line, and make
sure that there's no bather or
object in the spa tub
Step 2: Plug into power supply, press the
RESET button on the RCD
Step 3: Press ON/OFF, C/F, TEMP+
buttons once in sequence, enter
to self-checking system. If no error
code shown and returns to stand-
by mode, no failure is detected
and you can continue to use the
spa; if error code shown after self-
checking, please contact MSpa
Service Center
Please contact the MSpa Service Center.
Please change the water or contact
MSpa Service Center.
ERROR CODE CHART