background image

3-4

MS-9161 SSI Server Board

Once you enter 

PhoenixBIOS Setup Utility

, the Main Menu will appear on the

screen. On the Main Menu screen, you will see basic BIOS settings including system
time & date, and the setup categories the BIOS supplies. Use Arrow keys to move
among the items and menus, and make changes to the settings.

Main Menu

Use this menu for basic system configurations, such as time, date etc.

Advanced Menu

Use this menu to set up the items of special enhanced features available on your
system’s chipset.

Security Menu

Use this menu to set Supervisor and User Passwords and the Backup and Virus-
Check reminders.

Power Menu

Use this menu to specify your settings for power management.

Boot Menu

Use this menu to specify the priority of boot devices.

Exit Menu

This menu allows you to load the BIOS default values or factory default settings into
the BIOS and exit the BIOS setup utility with or without changes.

The Menu Bar

System Time

[09:10:11]

System Date

[05/25/2003]

Legacy Diskette A:/B:

[1.2MB 5¼ ]

8

Primary Master

     [None]

8

Primary Slave

     [None]

8

Secondary Master

      [CD-ROM]

8

Secondary Slave

     [None]

Large Disk Access Mode  :

[DOS]

Boot Summary Screen :

[Disabled]

System Memory  :

624KB

Extended Memory

:

510MB

PhoenixBIOS Setup Utility

    

    

    

    

    

 

 

 

 

 

 

 

 

 

 

Main     

     Advanced          Security          Power          Boot          Exit

<Tab>, <Shift+Tab>, or
<Enter> selects field.

Item Specific Help

 

F1   Help  

      

      

      

      

      

 ↑↓  

Select Item 

     

     

     

     

     

 -/+  Change Values    F9  Setup Defaults

 

 

 

 

 

Esc  Exit

   

   

   

   

   

  ↔ 

Select Menu

    

    

    

    

    

Enter Select   Sub-Menu   F10  Save and Exit

8

Содержание K8D Master3-133 FA4R

Страница 1: ...i G52 S9161X2 K8D Master3 133 Series MS 9161 v2 X SSI Server Board...

Страница 2: ...nt in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Notice 1 The changes or modifications not expres...

Страница 3: ...Business Machines Corporation Windows 95 98 2000 NT XP are registered trademarks of Microsoft Corporation Netware is a registered trademark of Novell Inc Award is a registered trademark of Phoenix Te...

Страница 4: ...e power cord such a way that people can not step on it Do not place anything over the power cord 8 Always Unplug the Power Cord before inserting any add on card or module 9 All cautions and warnings o...

Страница 5: ...g System 2 4 Memory 2 6 Installing DDR Modules 2 6 DIMM Configurations 2 7 Memory Population Rules 2 7 Power Supply 2 8 SSI 24 Pin Power Connector JPWR1 2 8 SSI 8 Pin Power Connector JPWR2 2 8 SSI 5 P...

Страница 6: ...terconnect Slots 2 19 PCI Interrupt Request Routing 2 20 Chapter 3 BIOS Setup 3 1 Entering Setup 3 2 Control Keys 3 2 Getting Help 3 3 General Help F1 3 3 The Menu Bar 3 4 The Main Menu 3 5 The Advanc...

Страница 7: ...ystem efficiency K8D Master3 133 Series SSI mainboards accommodate dual latest AMD OpteronTM DP processors in the 940 pin lidded ceramic micro PGA package and supports up to twelve 144 bit DDR registe...

Страница 8: ...PCI mode h AMD 8111 HyperTransport I O Hub HyperTransportTM I O Hub supports up to 800 megebytes per second with 200 MHz clock A 33 MHz 32 bit PCI 2 2 compliant bus interface supports up to eight ext...

Страница 9: ...Controller Incorporates an embedded microcontroller three System Management Bus SMBus interfaces a Chassis Management interface Bi color LED control an integrated EEPROM Fan control 12 ADC channels a...

Страница 10: ...Minimum Amount of Memory Required rate Hz 640x480 60 640X480 72 640X480 75 640X480 90 640X480 100 800X600 60 800X600 70 800X600 75 800X600 90 800X600 100 1024X768 60 1024X768 72 1024X768 75 1024X768...

Страница 11: ...12 DDR7 DDR10 DDR2 DDR4 DDR6 DDR11 DDR8 DDR9 BIO S PCI X1 PCI X2 PCI X3 PCI 2 IDE2 IDE1 USB Top Port 1 Bottom Port 2 Top Parallel Port Bottom COM Port VGA Port To Mouse Bottom Keyboard CFAN1 PFAN1 CFA...

Страница 12: ...R10 DDR2 DDR4 DDR6 DDR11 DDR8 DDR9 BIO S PCI X1 PCI X2 PCI X3 PCI 2 IDE2 IDE1 USB Top Port 1 Bottom Port 2 Top Parallel Port Bottom COM Port VGA Port To Mouse Bottom Keyboard CFAN1 PFAN1 CFAN2 SFAN1 S...

Страница 13: ...ratures monitor fan speed s monitor system voltage monitor chassis intrusion If one of the items above is abnormal the program main screen will be immediately shown on the screen with the abnormal ite...

Страница 14: ...up procedures While doing the installation be careful in holding the components and follow the installation procedures For some components if you install in the wrong orientation the compo nents will...

Страница 15: ...p 2 6 CFAN1 p 2 12 CFAN2 p 2 12 PFAN1 p 2 12 CPU1 p 2 3 J2 p 2 8 JPWR1 p 2 8 IDE2 1 p 2 10 SFAN1 p 2 12 JBAT1 p 2 17 JSSI1 p 2 14 FDD1 p 2 10 JUSB1 p 2 14 SFAN2 p 2 12 PCI Slots p 2 19 SCSI p 2 13 JSC...

Страница 16: ...ntended always install the CPU on the CPU1 socket 2 To install DUAL CPUs on the board you must use the same type of CPUs running at the same frequency Central Processing Unit CPU As processor technolo...

Страница 17: ...arrow on the Socket 940 Please note that the CPU can only fit in a correct orientation DO NOT use force to install the CPU into the socket 4 Place the CPU onto the socket and press it down firmly int...

Страница 18: ...fan contact your dealer to purchase and install them before turning on the computer reference figure MSI Reminds You Overheating Overheating will seriously damage the CPU and system always make sure t...

Страница 19: ...e is deeply inserted in the socket 3 The plastic clip at each side of the DIMM slot will automatically close The mainboard provides 12 slots for 184 pin DDR SDRAM DIMM Double In Line Memory Module mod...

Страница 20: ...Install Install Install Install DDR 4 Install Install Install Install Install Install Install Install DDR 5 Install Install Install Install Install Install Install Install DDR 6 Install Install Insta...

Страница 21: ...firmly into the connector SSI 8 Pin Power Connector JPWR2 This connector provides 12V power output to the CPU SSI 5 Pin Power Connector J2 This connector provides power supply to the System Management...

Страница 22: ...se KBD Clock Pin6 NC PIN SIGNAL 1 RED 2 GREEN 3 BLUE 4 N C 5 GND 6 GND 7 GND 8 GND 9 5V 10 GND 11 N C 12 SDA 13 Horizontal Sync 14 Vertical Sync 15 SCL 1 2 3 4 5 6 7 8 9 1 5 11 15 PIN SIGNAL 1 VCC 2 D...

Страница 23: ...n supplied by hard disk vendors for jumper setting instructions IDE1 Primary IDE Connector The first hard drive should always be connected to IDE1 IDE1 can connect a Master and a Slave drive You must...

Страница 24: ...ly support JBOD RAID 0 RAID 1 and RAID 10 for the Windows Linux and Netware operating systems Incorporating a single Phase Lock Loop PLL architecture supporting all four ports the SiI 3114 features in...

Страница 25: ...and should be connected to the 12V the black wire is Ground and should be connected to GND If the mainboard has a System Hardware Monitor chipset onboard you must use a specially designed fan with sp...

Страница 26: ...connector Pin Description Pin Description 1 DB 12 35 DB 12 2 DB 13 36 DB 13 3 DB 14 37 DB 14 4 DB 15 38 DB 15 5 DB P1 39 DB P1 6 DB 0 40 DB 0 7 DB 1 41 DB 1 8 DB 2 42 DB 2 9 DB 3 43 DB 3 10 DB 4 44 DB...

Страница 27: ...t panel switches and LEDs Pin Description Pin Description 1 Power LED 2 5Vs b 3 Key 4 NoConnection 5 Power LED 6 NoConnection 7 HDD Activity LED 8 System Status LED 9 HDD Activity LED 10 System Status...

Страница 28: ...16 bytes FIFOs You can attach a serial mouse or other serial devices directly to it PIN SIGNAL DESCRIPTION 1 DCD Data Carry Detect 2 SIN Serial In or Receive Data 3 SOUT Serial Out or Transmit Data 4...

Страница 29: ...em ID button D38 system ID LED are designed to facilitate the management of two or more MS 9161 systems When one of the systems crashes users may press the J5 button on the back panel of all systems o...

Страница 30: ...system is off Then return to 1 2 pin position Avoid clearing the CMOS while the system is on it will damage the mainboard Clear CMOS Jumper JBAT1 There is a CMOS RAM on board that has a power supply...

Страница 31: ...This jumper is used to disable enable the onboard National Semiconductor PC87431HM mBMC mini Baseboard Management Controller JBMC1 1 Disable Enable 1 3 1 3 J4 1 133MHz 66 100MHz 1 3 1 3 J25 1 PCI X 1...

Страница 32: ...ration The mainboard provides three Master 64 bit PCI also called PCI X bus slots and one 32 bit PCI slot 64 bit PCI X bus The bus has 64 data lines and runs at 133 for PCIX1 only 100 66 MHz With twic...

Страница 33: ...G0_A_GNT0 PCIX3 Bridge A AD20 B C D A G0_A_REQ1 G0_A_GNT1 SCSI BridgeA AD21 A G0_A_REQ2 G0_A_GNT2 PCI Interrupt Request Routing The IRQ acronym of interrupt request line and pronounced I R Q are hard...

Страница 34: ...each BIOS category described in this chapter are under continuous update for better system performance Therefore the description may be slightly different from the lat est BIOS and should be held for...

Страница 35: ...button You may also restart the system by simultaneously pressing Ctrl Alt and Delete keys Key F1 or Alt H Esc arrow keys or arrow keys Tab or Shift Tab Home or End PgUp or PgDn F5 or F6 or or Space F...

Страница 36: ...rom this field A sub menu contains additional options for a field parameter You can use arrow keys to highlight the field and press Enter to call up the sub menu Then you can use the control keys to e...

Страница 37: ...nders Power Menu Use this menu to specify your settings for power management Boot Menu Use this menu to specify the priority of boot devices Exit Menu This menu allows you to load the BIOS default val...

Страница 38: ...erly if you enter improper information for this category If your hard disk drive type is not matched or listed you can use Manual to define your own drive type manually If you select Manual related in...

Страница 39: ...fer Mode Selects the method for transferring the data between the hard disk and system memory Ultra DMA Mode Indicates the type of Ultra DMA Large Disk Access Mode Select DOS if you have DOS Select Ot...

Страница 40: ...y USB device other than the USB mouse Setting options Enabled Disabled F 1 H e l p F 1 H e l p F 1 H e l p F 1 H e l p F 1 H e l p Select Item Change Values F9 Setup Defaults E s c E x i t E s c E x i...

Страница 41: ...s for optimal system performance Dram Bank Interleave Interleave memory blocks across dram chip selects Options Auto Disabled Node Memory Interleave Interleave memory blocks across Processor Nodes BIO...

Страница 42: ...rrors detected in Dram during normal CPU requests Foreground scrubbing Options Enabled Disabled Chip Kill This item allows you to enable disable Chip Kill ECC on Nodes with all x4 ECC capable dimms Op...

Страница 43: ...ay time after the key is held down before it begins to repeat the keystroke Options 1 4 sec 1 2 sec 3 4 sec 1 sec I O Device Configuration The sub menu is used to configure I O Devices for optimal sys...

Страница 44: ...rial port A B Setting to Enabled allows users to configure the base I O address and IRQ of Port A Port B manually Options Enabled Disabled Base I O address It specifies the base I O address for Port A...

Страница 45: ...Only To operate the onboard parallel port in the EPP mode simultaneously choose EPP By choosing ECP the onboard parallel port will operate in ECP mode only Choosing Bi Dir will allow the onboard par a...

Страница 46: ...used to configure the onboard LAN device LAN Device Function Use this feature to enable or disable the onboard LAN device Option ROM Scan Use this feature to initialize device expansion ROM Enable Mas...

Страница 47: ...expansion ROM SATA OP ROM Control for SATA Use this feature to control the SATA option ROM Enable Master Use this feature to enable selected device as a PCI bus master Latency Timer Use this feature t...

Страница 48: ...Control This feature allows you to enable flow control Options None XON XOFF CTS RTS Console Type This feature allows you to enable the specified console type Options vt100 vt100 8bit ANSI 7bit ANSI...

Страница 49: ...nt Log Disabled Existing Event Log number 12 SYS Firmware Progress Enabled BIOS POST Watchdog Enabled System Event Log PhoenixBIOS Setup Utility Select this line to en disable COM port on BMC Item Spe...

Страница 50: ...0 SEL Message Rev 04 Sensor Type 01 Temperature Sensor Number 32 TMP_S2 SEL Event Type 81 Upper Non critical Going SEL Event Data 57 24 2A PhoenixBIOS Setup Utility This is an entry in the System Even...

Страница 51: ...case sensitive Pressing Enter at either Set Supervisor Password or Set User Password displays the following message Type the password and press Enter Repeat Set Supervisor Password Enter New Password...

Страница 52: ...and this option is disabled BIOS assumes the user is booting Options Enabled Disabled Fixed disk boot sector Write protects the boot sector on the hard disk for virus protection It requires a passwor...

Страница 53: ...ower shutdown Options Off 1 min 2 min 4 min 6 min 8 min 12 min 16 min Auto Suspend Timeout This feature allows you to specify the inactivity period required after Standby to Suspend maximum power shut...

Страница 54: ...predetermined time Options On Off Resume Time The time format is HH MM SS Resume Date The date format is MM DD YYYY Power Safe This setting specifies whether your system will reboot after a power fai...

Страница 55: ...ce s priority first select it with the up or down arrows and move it up or down using the and keys Use this menu to arrange and specify the priority of the devices from which the BIOS will attempt to...

Страница 56: ...hanges The option allows users to restore all of the BIOS settings to previous values Save Changes The option allows users to save the changes without exiting Setup The Exit Menu The following section...

Страница 57: ...S setup utility and allows you to configure the SCSI subsystem for optimum use You may need to run the SCSI BIOS setup utility when You want to change the default SCSI controller settings for customiz...

Страница 58: ...he menu will list two categories for you to choose what to do with the SCSI channel Move the cursor to the desired function and press Enter Power on the computer and the system will start POST Power O...

Страница 59: ...configurations SCSI Disk Utilities Use this option to manage the attached SCSI device Would you like to configure the SCSI controller or run the SCSI Disk Utilities Select the option and press Enter C...

Страница 60: ...to have the SCSI bus function properly and reliably termination at the ends of the SCSI bus is necessary Proper termination can ensure signal on the SCSI bus will not reflect and cause data loss or er...

Страница 61: ...boot logical unit number LUN If multiple LUN support is disabled specifying a number here is useless Setting options 0 7 SCSI Device Configuration Press Enter and the following sub menu screen appears...

Страница 62: ...low other I O processes and thus optimizes the SCSI bus performance Setting options Yes No SCSI Device ID 0 1 2 3 4 5 6 7 Sync Transfer Rate MB Sec 320 320 320 320 320 320 320 320 Packetized Yes Yes Y...

Страница 63: ...he SCSI bus the first time the SCSI controller is initialized Setting options Enabled Disabled Display Ctrl A Message During BIOS Initialization When enabled the message Press Ctrl A for SCSISelect TM...

Страница 64: ...ed in the device drivers However this option is not supported by the BIOS Support Removable Disks Under Int13 as Fixed Disks When Boot Only is selected only the removable media drive designated as the...

Страница 65: ...oning properly Verifying function will scan for media defects on the disk SCSI ID 0 HITACHI DK32DJ 18MW Firmware G2G2 Capacity 17GB Format Disk Verify Disk Media Disk Utilities AIC 7901 at slot 07 03...

Отзывы: