background image

i

English Version

G52-S9136X1

MS-9136 SSI Server Board

E7520 Master Series

Содержание E7520 Master S2M

Страница 1: ...i English Version G52 S9136X1 MS 9136 SSI Server Board E7520 Master Series...

Страница 2: ...nt in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Notice 1 The changes or modifications not expres...

Страница 3: ...98 2000 2003 NT XP are registered trademarks of Microsoft Corporation Netware is a registered trademark of Novell Inc Award is a registered trademark of Phoenix Technologies Ltd AMI is a registered tr...

Страница 4: ...or module 9 All cautions and warnings on the equipment should be noted 10 Never pour any liquid into the opening that could damage or cause electrical shock 11 If any of the following situations arise...

Страница 5: ...Rules 2 6 Installing DDR Modules 2 6 Memory Speed CPU FSB Support Matrix 2 7 Power Supply 2 8 SSI 24 Pin Power Connector JPWR1 2 8 SSI 8 Pin Power Connector JPWR2 2 8 Back Panel 2 9 Connectors 2 10 F...

Страница 6: ...p 3 3 General Help F1 3 3 The Menu Bar 3 4 Main 3 6 System Summary 3 8 Advanced 3 9 IPMI Optional 3 16 Security 3 19 Boot 3 21 Exit 3 22 Appendix A SCSI BIOS Setup Optional A 1 Entering SCSI BIOS A 2...

Страница 7: ...B 7 1 Overview B 7 2 Supported Browsers B 7 3 Typical Custom and Compact Installations B 7 4 Installing Adaptec Storage Manager on Windows B 8 5 Installing Adaptec Storage Manager on Linux B 11 Using...

Страница 8: ...boards based on Intel Lindenhurst Hance Rapids chipsets for optimal system efficiency Designed to fit the advanced Intel XeonTM processors in the 604 pin package the E7520 Master Series provide a solu...

Страница 9: ...xpress Bus specification v1 0a compliant HDD Interface h SCSI interface supported by Adaptec AIC 7902 Ultra 320 SCSI controller Optional Integrated Adaptec AIC 7902 Ultra 320 SCSI adapter Supports dua...

Страница 10: ...2001 system design compliant Dimension h SSI EEB 3 0 Form Factor 12 0 x 13 0 inch Mounting h 17 mounting holes in total including CPU fan mounting holes MSI Reminds You Enabling the functionality of H...

Страница 11: ...MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 2MB 4MB 2MB 2MB 2MB 4MB 2MB 2MB 2MB 4MB 2MB 2MB 2MB 4MB 2MB 2MB 2MB 4MB 2MB 2MB 4MB 4MB 2MB 2MB 4MB 4MB 2MB 2MB 4MB 4MB 2MB 2MB 4MB 4MB 2MB 2MB 4MB 4MB 2MB 4MB 4MB 6MB 2...

Страница 12: ...or shared NIC RMCP Ability to update firmware inband unattended Remote access security MD5 Out of band environmental monitoring and alerting Secure remote power control and system reset over Serial or...

Страница 13: ...Mouse B Keyboard LAN JPWR2 PCI 1 IDE2 IDE1 FDD1 JCI1 SATA1 SATA2 FAN6 FAN5 FAN3 CN21 CN39 FAN2 JBAT1 CN40 J1 J2 J3 COM2 CN31 J4 J5 Adaptec AIC 7902W Intel Hance Rapids ATI RADEON SCSI 2 Top Parallel P...

Страница 14: ...res monitor fan speed s monitor system voltage monitor chassis intrusion If one of the items above is abnormal the program main screen will be immediately shown on the screen with the abnormal item hi...

Страница 15: ...up procedures While doing the installation be careful in holding the components and follow the installation procedures For some components if you install in the wrong orientation the compo nents will...

Страница 16: ...1 8 p 2 5 FAN5 p 2 10 SOCKET 604 mPGA SOCKET 604 mPGA JPWR2 p 2 8 PCI Slots p 2 19 SCSI1 2 p 2 14 JSCSI1 p 2 14 CN15 p 2 15 COM2 p 2 16 IDE2 1 p 2 11 JSSI1 p 2 13 FAN1 p 2 10 JPWR1 p 2 8 JCI1 p 2 10 J...

Страница 17: ...op to prevent overheating If you do not find the Heat Sink and cooling fan contact your dealer to purchase and install them before turning on the computer Central Processing Unit CPU MSI Reminds You O...

Страница 18: ...into the socket and can not be seen Please note that any violation of the correct installation procedures may cause permanent damages to your mainboard 5 Press the CPU down firmly into the socket and...

Страница 19: ...66 DDR333 memory interface supports x72 ECC registered DDR266 DDR333 DIMMs using 128 Mb 256 Mb 512Mb and 1 Gb Maximim 16 GB support with DDR333 up to two stacked DIMMs 1 Gb x4 DRAMs Maximim 32 GB supp...

Страница 20: ...e Ranks Single Rank Single Rank Single Rank E 1 Dual Rank 2 Single Ranks Dual Rank Single Rank Single Rank E DDR266 DIMM slot population DIMM Configuration DIMM 1 2 DIMM 3 4 DIMM 5 6 DIMM 7 8 1 Single...

Страница 21: ...ule vertically into the DIMM slot Then push it in until the golden finger on the memory module is deeply inserted in the socket 3 The plastic clip at each side of the DIMM slot will automatically clos...

Страница 22: ...e pins are aligned Then push down the power supply firmly into the connector SSI 8 Pin Power Connector JPWR2 This connector provides 12V power output to the CPU JPWR2 1 8 5 4 PIN SIGNAL 13 3 3V 14 12V...

Страница 23: ...VCC Pin5 Mouse KBD Clock Pin6 NC PIN SIGNAL 1 RED 2 GREEN 3 BLUE 4 N C 5 GND 6 GND 7 GND 8 GND 9 5V 10 GND 11 N C 12 SDA 13 Horizontal Sync 14 Vertical Sync 15 SCL 1 2 3 4 5 6 7 8 9 1 5 11 15 PIN SIG...

Страница 24: ...wire is the positive and should be connected to the 12V the black wire is Ground and should be connected to GND If the mainboard has a System Hardware Monitor chipset onboard you must use a specially...

Страница 25: ...ard disks on cable you must configure the second drive to Slave mode by setting its jumper Refer to the hard disk docu mentation supplied by hard disk vendors for jumper setting instructions ATA100 Ha...

Страница 26: ...for easy management of the storage subsystems Both connectors support 1st generation serial ATA data rates of 150 MB s and are fully compliant with Serial ATA 1 0 specifications PIN SIGNAL PIN SIGNAL...

Страница 27: ...LEDs JSSI1 34 Standby Power 5V PowerLED HDD LED ResetSwitch Power Switch Giga bit LAN1 LED Giga bit LAN2 LED SMBus Chassis Intruder 33 2 1 Pin Description Pin Description 1 Power LED 2 5Vs b 3 Key 4...

Страница 28: ...the SCSI connectors Pin Description Pin Description 1 DB 12 35 DB 12 2 DB 13 36 DB 13 3 DB 14 37 DB 14 4 DB 15 38 DB 15 5 DB P1 39 DB P1 6 DB 0 40 DB 0 7 DB 1 41 DB 1 8 DB 2 42 DB 2 9 DB 3 43 DB 3 10...

Страница 29: ...GND 5 3 3RS Pin Definition PIN SIGNAL 1 SMBUS_SDA 2 GND 3 SMBUS_SCL 4 NC CN28 Pin Definition CN15 Pin Definition PIN SIGNAL 1 SMBCLK 2 SMBDATA 3 NC 4 GND 5 VCC3 4 pin I2 C Bus Connector CN28 5 pin I2...

Страница 30: ...ify the broken system and get it fixed By pressing the CN31 button again the system ID LED will go out CN31 Back Panel Serial Port Connector COM 2 The mainboard provides one 9 pin header as serial por...

Страница 31: ...upply from external battery to keep the data of system configuration With the CMOS RAM the system can automatically boot OS every time it is turned on If you want to clear the system configuration use...

Страница 32: ...into the floppy drive before powering on the system After powered on the system will read the boot disk and enter DOS This enables you to update the BIOS with a Flash utility if necessary BIOS Boot Bl...

Страница 33: ...I X slot connecting to PXH channel B 3 3V device only MSI Reminds You When adding or removing expansion cards make sure that you unplug the power supply first Meanwhile read the documentation for the...

Страница 34: ...ATIVGA AD17 PXIRQ0 NA NA NA PXREQ0 PXGNT0 GIGA LAN0 AD18 PXIRQ1 NA NA NA PXREQ1 PXGNT1 GIGA LAN1 AD19 PXIRQ2 NA NA NA PXREQ2 PXGNT2 PCIX 64 Routing From PXH Channel A 100MHz PCI DEVICE IDSEL INT A INT...

Страница 35: ...O 131 BMC_Heartbeat O 133 BMC_SMI 135 COM_EXCH_DIS O 139 COM_SHUT O 141 5VSB 143 LPC_AD1 4 LPC_AD2 6 LPC_AD3 8 GND 10 I LPC_CLK 12 LPC_RST 14 LPC_FRAME 16 O LPC_INT 20 GND 18 O LPC_DRQ 22 I POST I2C_R...

Страница 36: ...each BIOS category described in this chapter are under continuous update for better system performance Therefore the description may be slightly different from the lat est BIOS and should be held for...

Страница 37: ...r pressing the RESET button You may also restart the system by simultaneously pressing Ctrl Alt and Delete keys Key F1 or Alt H Esc arrow keys or arrow keys Home or End PgUp or PgDn F5 or F6 or or Spa...

Страница 38: ...rom this field A sub menu contains additional options for a field parameter You can use arrow keys to highlight the field and press Enter to call up the sub menu Then you can use the control keys to e...

Страница 39: ...available on your system s chipset IPMI Optional This setup screen is for IPMI Intelligent Platform Management Interface configura tions and appears only when the MS 9569 BMC card for Server Manageme...

Страница 40: ...Supervisor and User Passwords Boot Use this menu to specify the priority of boot devices Exit This menu allows you to load the BIOS default values or factory default settings into the BIOS and exit th...

Страница 41: ...e Note that the specifications of your drive must match with the drive table The hard disk will not work properly if you enter improper information for this category If your hard disk drive type is no...

Страница 42: ...fine the HDD parameters Multi Sector Transfers Any selection except Disabled determines the number of sectors transferred per block LBA Mode Control Enabling LBA causes Logical Block Ad dressing to be...

Страница 43: ...for basic system information and configuration Each item includes none one or more setup items Use the Up Down arrow keys or Tab to highlight the item or field you want to modify and use the or key to...

Страница 44: ...Function or unreliability and instability may occur Settings Enabled Disabled Items in the menu are divided into several sub menus Each sub menu provides more settings To enter the sub menu highligh...

Страница 45: ...y or Both to activate chipset IDE interface s installed on your system board MSI Reminds You Enabling the functionality of Hyper Threading Technology for your computer system requires ALL of the follo...

Страница 46: ...ng modes through any signal from LAN or any event on PME Power Management Event Settings Enabled and Disabled Wake On Ring The setting specifies whether the system will be awakened from power saving m...

Страница 47: ...configure the onboard video device Onboard VGA Control Use this feature to enable or disable the onboard VGA controller Peripheral Configuration The sub menu is used to configure I O devices for optim...

Страница 48: ...mary screen during boot up Options Enabled Disabled Boot time Diagnostic Screen Select Enabled if you want to view the system diagnostic screen during boot time Options Enabled Disabled QuickBoot Mode...

Страница 49: ...mmediately Press Y and Enter the BIOS will clear all DMI event logs right away Clear All DMI Event Logs When this setting is set to Yes the DMI event log will be cleared at next POST stage Then the BI...

Страница 50: ...er a modem is used Options None XON XOFF CTS RTS Console Type This feature allows you to enable the specified console type Options VT100 VT100 8bit PC ANSI 7bit PC ANSI UT100 VT UTF8 FIFO Level This f...

Страница 51: ...PhoenixBIOS Setup Utility Main System Summary Advanced IPMI Security Boot Exit Disables Enables triggers for system sensor events inside BMC Baseboard Management Controller Item Specific Help IPMI Sp...

Страница 52: ...Disabled BIOS POST Watchdog You can enable the system watch dog timer a hardware timer that generates either an NMI or a reset when the software that it monitors does not respond as expected each tim...

Страница 53: ...SEL Record Type 02 System Event Record Timestamp 01 13 2004 10 50 08 Generator Id 20 00 SEL Message Rev 04 Sensor Type 01 Temperature Sensor Number 32 TMP_S2 SEL Event Type 81 Upper Non critical Going...

Страница 54: ...Setup The pass words are not case sensitive Pressing Enter at either Set Supervisor Password or Set User Password displays the following message Type the password and press Enter Repeat Set Superviso...

Страница 55: ...g of the supervisor password If the supervisor password is set and this option is disabled BIOS assumes the user is booting Options Enabled Disabled Fixed disk boot sector Write protects the boot sect...

Страница 56: ...all such devices To change a device s priority first select it with the up or down arrows and move it up or down using the and keys Use this menu to arrange and specify the priority of the devices fr...

Страница 57: ...ce of the mainboard Discard Changes The option allows users to restore all of the BIOS settings to previous values Save Changes The option allows users to save the changes without exiting Setup Exit T...

Страница 58: ...S setup utility and allows you to configure the SCSI subsystem for optimum use You may need to run the SCSI BIOS setup utility when You want to change the default SCSI controller settings for cus tomi...

Страница 59: ...en will appear after you select the SCSI channel you intend to manage The menu will list two categories for you to choose what to do with the SCSI channel Move the cursor to the desired function and p...

Страница 60: ...onfigurations SCSI Disk Utilities Use this option to manage the attached SCSI device Would you like to configure the SCSI controller or run the SCSI Disk Utilities Select the option and press Enter Co...

Страница 61: ...e reselection fails due to a parity error SCSI Controller Termination In order to have the SCSI bus function properly and reliably termination at the ends of There are 8 items in the Configure View SC...

Страница 62: ...options 0 15 Boot LUN Number If a boot device has multiple logical units you must specify the boot logical unit number LUN If multiple LUN support is disabled specifying a number here is useless Sett...

Страница 63: ...low other I O processes and thus optimizes the SCSI bus performance Setting options Yes No SCSI Device ID 0 1 2 3 4 5 6 7 Sync Transfer Rate MB Sec 320 320 320 320 320 320 320 320 Packetized Yes Yes Y...

Страница 64: ...he SCSI bus the first time the SCSI controller is initialized Setting options Enabled Disabled Display Ctrl A Message During BIOS Initialization When enabled the message Press Ctrl A for SCSISelect TM...

Страница 65: ...ed in the device drivers However this option is not supported by the BIOS Support Removable Disks Under Int13 as Fixed Disks When Boot Only is selected only the removable media drive designated as the...

Страница 66: ...ID 12 No device SCSI ID 13 No device SCSI ID 14 No device SCSI ID 15 No device Select SCSI Disk and press Enter AIC 7902 B at slot 0A 03 07 00 SCSI ID 0 HITACHI DK32DJ 18MW SCSI ID 1 No device SCSI I...

Страница 67: ...you want to perform Format Disk The utility performs low level formatting of a hard disk drive The function might take several hours to complete Verify Disk Media This utility verifies that the drive...

Страница 68: ...latest generation of the ATA interface SATA hard drives deliver blistering transfer speeds of up to 150MB sec Serial ATA uses long thin cables making it easier to connect your drive and improving the...

Страница 69: ...aptec s HostRAID technology Operating system independent configuration and RAID creation using Adaptec RAID Configuration ARC Easy array configuration and status using Adaptec Storage ManagerTM Browse...

Страница 70: ...of the controller s built in BIOS code You start ARC by pressing Ctrl A during BIOS startup For details see Adaptec RAID Configuration Utility Array Configuration Utility ACU A DOS BIOS application us...

Страница 71: ...rl A when prompted to enter the ARC utility For instructions on creating an array from the BIOS see Adaptec RAID Configuration Utility For a simple volume skip to Step 4 4 When the array is finished b...

Страница 72: ...em In this scenario you are installing the driver in a new Linux system To install the driver 1 Obtain a driver disk from either the Web site or the product CD 2 Restart the computer 3 If creating an...

Страница 73: ...the driver disk you created see Step 1 and press any key to continue 7 Follow the prompts to set up your preferred environment 8 Continue with the Linux installation according to the SuSE documentatio...

Страница 74: ...Supports local and remote management however Adaptec SNMP is not included Custom For expert users Primarily used on Web servers or when you want to make sure SNMP and Notifier are available for a man...

Страница 75: ...oose a setup type and click Next 8 When you see the Destination Folder click Next 9 When you see the Setup Information click Next The Setup Status window shows progress using a scroll bar Before the s...

Страница 76: ...these settings Active Scripting Allow per session cookies not stored If you are using a proxy server to access the Internet you must bypass the proxy server to access the Adaptec Storage Manager Web...

Страница 77: ...ne Ensure that Enable Javascript for Navigator is checked 5 Exit Navigator then restart it This enables any settings you have modified 6 You are now ready to proceed to Using Adaptec Storage Manager B...

Страница 78: ...Click Next The Running Non Interactive Setup window displays the files being loaded onto the system 7 Click Next when prompted A Setup Complete window appears 8 Click Complete A message window appear...

Страница 79: ...at has Managed System Components see Typical Custom and Com pact Installations You can manage a system remotely from a system that does not contain a RAID controller These same Windows and Linux syste...

Страница 80: ...TCP IP connection The Web service can be installed on the same remote system as the browser the system with the RAID controller installed or a third system Communication security is ensured because Se...

Страница 81: ...for the first time To create the certificate 1 When the Security Alert window appears click View Certificate 2 On the Certificate window click Install Certificate 3 On the Certificate Import wizard wi...

Страница 82: ...ailed infor mation and allow you to perform actions or change settings on a specific aspect of your storage subsystem These are Events Options Help Properties Tasks Immediately following the header fr...

Страница 83: ...on and options specific to that device or channel At the top of the Physical Devices view grouped to the right of View are three view selection buttons These buttons select the physical devices connec...

Страница 84: ...ive may be shown in dark gray The segment at the end of the drive may vary in size from drive to drive because in addition to the RAID signature the controller may also limit the usable capacity of ea...

Страница 85: ...vertically and along side them are the capacity name and type of array Selecting an array by clicking on it will highlight the following in amber All the drives or segments that form the array in the...

Страница 86: ...e controller s BIOS and initialize drives Managing Arrays Use the Manage Arrays option to view array properties and members and delete arrays The following sections describe these operations in greate...

Страница 87: ...eate an array 1 Turn on your computer and press Ctrl A when prompted to access the ARC utility 2 From the ARC menu select Array Configuration Utility ACU 3 From the ACU menu select Create Array 4 Sele...

Страница 88: ...later run a consistency check This is normal and is not a cause for concern The ACU allows you to use drives of different sizes in a RAID 1 During a build operation however only the smaller drive can...

Страница 89: ...Disk Utilities enable you to format or verify the media of your Serial ATA hard disks To access the disk utilities 1 Turn on your computer and press Ctrl A when prompted to access the ARC utility 2 F...

Страница 90: ...s and some entry level servers Serial ATA SATA is a successor to parallel ATA which is sometimes referred to as PATA available space segment Unused space on an initialized disk from which logical devi...

Страница 91: ...oining of physical or logical drives in sequential order consistency check command Command that reads all the blocks of a RAID 1 to determine if the blocks are consistent Any inconsistent blocks are f...

Страница 92: ...D 1 arrays See also Redundant foreign disk Disk that has previously been initialized on another Adaptec RAID controller The RAID signature on the disk allows the RAID controller to identify whether or...

Страница 93: ...isk M mirrored array mirroring See RAID 1 monitoring Process of receiving displaying and logging system events O offline array Array that can no longer be accessed optimal The state of an array when i...

Страница 94: ...Provides redundancy by storing identical copies on two drives See also mirrored array mirroring RAID signature The area on each disk reserved for use by the RAID controller RAID volume Concatenates tw...

Страница 95: ...array striped array See RAID 0 T task An operation that occurs only on the RAID controller asynchronous to all other operations for example initializing a disk or verifying an array Some tasks can ta...

Отзывы: