4.1. Displayed data
The information shown on the display when the following types of alternator/voltage regulator is
diagnosed: Lamp, P-D, C, SIG, RLO (see fig. 4 - 8):
VOLTAGE, DC
– rate of generation voltage that is provided by alternator/regulator.
DFM, %
– duty ratio of PWM signal received through FR channel (on-condition rate of rotor
winding).
АМР, DC
– for alternator - it’s a load; for voltage regulator - the rate of the current that is supplied
to the rotor excitation winding; for starter - the rate of the current that is consumed by starter
electric motor.
АМР, АС
– rate of the alternator alternating current output, ripples.
ТАСНОМЕТЕR
– drive speed rate.
D
– rate of generation voltage that is set by the bench.
Р
– rate of the on-condition of rotor winding.
Alternator/Starter Voltage regulator
Figure 4 – Bench display during the diagnostics
of alternator/voltage regulator of type Lamp type or starter