The possibility to centrifuge test tubes of different dimensions should be avoided at all
times. However, if it is absolutely necessary then opposite loads should be the same
weight.
Care should be taken to load the rotor holes asymmetrically.
8.
Ensure that all holes are being used in the rotor.
9. Only use tubes made from a plastic material.
Never use glass test tubes.
11. Fill in all test tubes equally in order to protect the centrifuge against imbalance.
12. Always use tubes that are in good condition and discard any that show signs of wear.
13. Infectious materials should be processed in closed test tubes only.
14. It is prohibited to centrifuge explosive and inflammable materials.
15. It is prohibited to centrifuge substances prone to reaction in result of delivery of high
energy during centrifugation.
4.6 Hazards and precautions
1.
In order to avoid damaging the centrifuge in any way, the user should read and
understand the instruction manual before operating the Micro centaur Plus.
2.
Un-trained personnel should never operate the centrifuge.
3.
The centrifuge must not be transported with the rotor mounted on the motor shaft.
4.
The centrifuge should only be used in conjunction with original rotors and spare parts.
5.
If the user discovers a fault with the centrifuge, a qualified service engineer should be
contacted through MSE (UK) Ltd.
6.
Do not switch the centrifuge on if it is not installed properly or if the rotor is not fitted
correctly.
7.
The centrifuge must not be operated in places where there is a risk of extreme hot or
cold temperatures.
8.
Do not use flammable or highly volatile materials in the centrifuge.
9.
Users are advised to take extreme care when centrifuging toxic or contaminated
substances.
10. The appropriate decontamination procedure should be adhered to when cleaning any
parts of the centrifuge that has been in contact with any toxic or hazardous material.
11. Do not open the lid manually when the rotor is still turning.
12. Do not exceed the load limit set by the manufacturer.
13. Rotors are intended for fluids of average homogeneous density equal to 1.2 g/cm
3
or
smaller when centrifugation is carried out at maximum speed. When fluids of higher
density are used, then it may be necessary to reduce the speed.
14. Do not use the rotors that have signs of corrosion or other mechanical defects.
15. Do not use highly corrosive substances, which could cause material impairment and
lower the mechanical properties of rotor.
16. Do not use plastic rotors and accessories that have not been recommend by MSE
Centrifuges Ltd.
17. Only commercial plastic test tubes should be used.
18. Ensure that the test tubes are in good condition and show no signs of damage or wear.
19. Do not run the centrifuge without the rotor.
20. Do not run the centrifuge without the lid on the rotor.
21. Do not move the centrifuge whilst in use.
22. Maintain a safe distance from the centrifuge whilst in use.
23. Do not place objects on the centrifuge.