background image

Programmable

DIGITAL-7 PLUS

LT BLUE

GREEN

TO CAM SYNC
PICKUP

GREEN

PN 8860

HARNESS

GREEN

HEAVY BLACK TO BATTERY

3

N

 PI

C

B

A

Pink - Step 1 Retard/Gear 2
Violet - Step 2 Retard/Gear 3
Tan - Step 3 Retard/Gear 4

Red - To switched 12 volts
White - Amplifier Trigger
Yellow - Shift Light
Brown/White - RPM/Time/PSI Switch
Dark Blue -

VIOLET

TO

AP

M

SENSOR

Burnout Rev Limit overrides other rev limits, 
Disables Launch History and Slew Rev Limit
(Wire to outside source to be switched by crew.)

Launch Rev Limit to Line Lock or Clutch Switch
Reset for Shift Light, Gear Indicator, Launch Ramp,
Gear Curve, Disables Slew when Activated. 

Light Blue -

R

VIOLET

Gray

NOTE:
Change following in Prodata-
Test Spark ON         => Test Spark OFF
CylCnt Tach Trigger  => Tach Timing
RevMax OutCam      => OutRev

Gray

Plugs into number 

2 module only

T

DA A

U P T

O T U

MSD SYSTEM    Installing to a Programmable Digital 7, PN 7531

THE  MSD-8  PLUS  CAN  BE  USED  IN  TANDEM  WITH  A 

PROGRAMMABLE  7-PLUS.  THIS  SYSTEM  DELIVERS  THE 

POWER OF THE MSD-8 WITH THE ADVANCED PC TUNING 

CAPABILITIES OF THE PN 7531 IGNITION.

Limited Warranty

 

M

SD warrants this product to be free from defects in material and workmanship under its intended normal use*, 

when properly installed and purchased from an authorized MSD dealer, for a period of one year from the date of 

the original purchase. This warranty is void for any products purchased through auction websites. If found to be 

defective as mentioned above, it will be repaired or replaced at the option of MSD. Any item that is covered under 

this warranty will be returned free of charge using Ground shipping methods. 

  This shall constitute the sole remedy of the purchaser and the sole liability of MSD. To the extent permitted by 

law, the foregoing is exclusive and in lieu of all other warranties or representation whether expressed or implied, 

including any implied warranty of merchantability or fitness. In no event shall MSD or its suppliers be liable for special 

or consequential damages.

  *Intended normal use means that this item is being used as was originally intended and for the original application 

as sold by MSD. Any modifications to this item or if it is used on an application other than what MSD markets the 

product, the warranty will be void. It is the sole responsibility of the customer to determine that this item will work for 

the application they are intending. MSD will accept no liability for custom applications. 

Service

  In case of malfunction, this MSD component will be repaired free of charge according to the terms of the warranty. 

When returning MSD components for warranty service, 

Proof of Purchase must be supplied for verification. After 

the warranty period has expired, repair service is based on a minimum and maximum fee.

 

All  returns  must  have  a  Return  Material  Authorization  (RMA)  number

  issued  to  them  before 

being returned. To obtain an RMA number please contact MSD Customer Service at 1 (888) MSD-7859 or visit 

our  website  at  www.msdperformance.com/rma  to  automatically  obtain  a  number  and  shipping  information. 

  When returning the unit for repair, leave all wires at the length in which you have them installed. Be sure to include 

a detailed account of any problems experienced, and what components and accessories are installed on the vehicle. 

The repaired unit will be returned as soon as possible using Ground shipping methods (ground shipping is covered 

by warranty). For more information, call MSD at (915) 855-7123. MSD technicians are available from 7:00 a.m. to 

5:00 p.m. Monday - Friday (mountain time).

M S D  

•   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4

© 2012 Autotronic Controls Corporation

FRM29363 

 

 

 

 

Revised 04/12   

 

 

Printed in U.S.A.

Содержание MSD-8 Plus

Страница 1: ...tems Note that when using a single coil both coil positive wires must be connected to the coil RPM LIMITERS The MSD 8 Plus Ignition is equipped with a 2 Step Rev Control The Ignition will accept two rpm modules so two different rev limits can be set One rev limit can be used for over rev protection while the second limit can be activated on the starting line for a lower rpm limit to assist in stag...

Страница 2: ...ht or other add on rpm activated devices The Tach Output Terminal produces a 12 volt square wave signal with a 20 duty cycle SPARK PLUGS AND WIRES Spark plug wires are very important to the operation of your ignition system A good quality helically wound wire and proper routing are required to get the best performance from your ignition such as the MSD Heli Core or 8 5mm Super Conductor Note Solid...

Страница 3: ... only wire that makes electrical contact with the coil negative terminal COIL 2 HEAVY BLACK This wire connects to a good ground either at the battery negative terminal or to the engine BAT HEAVY RED GRAY BAT TACH TACH 2 STEP IGNITION Connects to a switched 12 volt source Such as the ignition key or switch RED WHITE This wire is used to connect to the points electronic ignition amplifier output or ...

Страница 4: ...If you experience a problem with your MSD our research has shown that the majority of problems are due to improper installation or poor connections The Troubleshooting section has several checks and tests you can perform to ensure proper installation and operation of the MSD If you have any questions concerning your MSD call our Customer Support Department at 915 855 7123 7 6 mountain time MISSES ...

Страница 5: ...in the Off position 2 Remove the coil wire from the distributor cap and set the terminal approximately 1 2 from ground 3 Disconnect the MSD White wire from the distributor s points or ignition amplifier 4 Turn the ignition to the On position Do not crank the engine 5 Rapidly tap the White wire to ground several times the first 3 4 times will not spark When the wire is pulled from ground a spark sh...

Страница 6: ...shes check for a coil problem The following wiring diagrams illustrate numerous installations on different vehicles and applications If you experience difficulties when installing your MSD contact our Customer Support Department at 915 855 7123 7 6 Mountain time or e mail us at msdtech msdignition com COIL TERMINALS MSD supplies heavy duty nickel plated terminals for the connections There is also ...

Страница 7: ... TO BATTERY NEGATIVE HEAVY RED TO BATTERY POSITIVE BLUE GRAY MSD SYSTEMS With an MSD Timing Control COIL 1 COIL 1 COIL 2 COIL 2 TO SWITCHED 12 VOLTS PN 8261 PN 8261 BLACK ORANGE BLACK ORANGE TO CHASSIS HEAVY BLACK TO BATTERY NEGATIVE HEAVY RED TO BATTERY POSITIVE BLUE GRAY NOTE WHEN USING A SINGLE COIL BOTH COIL POSITIVE TERMINALS MUST BE CONNECTED TO THE COIL EITHER CONNECT BOTH ORANGE WIRES TO T...

Страница 8: ...n lieu of all other warranties or representation whether expressed or implied including any implied warranty of merchantability or fitness In no event shall MSD or its suppliers be liable for special or consequential damages Intended normal use means that this item is being used as was originally intended and for the original application as sold by MSD Any modifications to this item or if it is us...

Отзывы: