background image

INSTALLATION INSTRUCTIONS 

3

M S D  

•  

W W W . M S D P E R F O R M A N C E . C O M

  •   ( 9 1 5 )   8 5 5 - 7 1 2 3   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4

  

2-PIN CONNECTOR, ACCESSORIES

PINK 

Pin-B 

Step Retard. When 12-volts are supplied, the Step Retard is activated.

BLUE 

Pin-A 

Two-Step. When 12-volts are supplied, the RevLaunch rpm value is active. 

  

16-PIN CONNECTOR WIRE LOCATION

GRAY 

Pin-A Ground

PINK 

Pin-B 

12 Volt Supply

BROWN/WHITE 

Pin-C 

Cam Sensor Signal

RED/GREEN 

Pin-D Coil-2

BROWN/GREEN  Pin-E Coil-4

WHITE/BLUE 

Pin-F Coil-6

VIOLET/BLUE 

Pin-G Coil-8

YELLOW 

Pin-H Tach

BROWN 

Pin-J 

Sensor Ground

LT. GREEN 

Pin-K 

MAP Sensor Signal

RED 

Pin-L Coil-7

GREEN 

Pin-M Coil-5

LT. BLUE 

Pin-N Coil-3

VIOLET 

Pin-P Coil-1

ORANGE/YELLOW 

Pin-R 

Crank Sensor Signal

ORANGE 

Pin-S 

5 Volt Supply

Figure 1 Wiring the MSD 6LS-2 Controller. 

Содержание 6LS-2 PN 6012

Страница 1: ...lation EFI This Controller can also be used in stock EFI applications by using accessory Harness PN 88862 This Harness allows the PN 6012 Controller to tap into the sensor signals without interrupting...

Страница 2: ...y CAMSHAFT SENSOR 3 PIN BROWN WHITE Pin C Cam Sensor Signal BROWN Pin B Sensor Ground ORANGE Pin A 5 Volt Supply MAP CONNECTOR 3 PIN OPTIONAL BROWN Pin A Sensor Ground LT GREEN Pin B MAP Sensor Signal...

Страница 3: ...pm value is active 16 PIN CONNECTOR WIRE LOCATION GRAY Pin A Ground PINK Pin B 12 Volt Supply BROWN WHITE Pin C Cam Sensor Signal RED GREEN Pin D Coil 2 BROWN GREEN Pin E Coil 4 WHITE BLUE Pin F Coil...

Страница 4: ...the Ignition Controller Saves and Transfers Whenever a change is made to a program it either must be saved to a file in your PC or it needs to be transferred to the Controller You will notice that whe...

Страница 5: ...a timing curve by using the RPM Table or MAP Table through your PC there must NOT be a Timing Module installed Power up with a module installed will override the saved timing plot This is a Manifold A...

Страница 6: ...o 12 volts Default is 10 IDLE TIMING CONTROL This is defaulted at Control DISABLE When switched to ENABLE the controller will alter the ignition timing constantly to search for the best idle qualities...

Страница 7: ..._______________________________________________________________ _________________________________________________________________________________________________________________________ ______________...

Страница 8: ...y warranty For more information call MSD at 915 855 7123 MSD technicians are available from 7 00 a m to 5 00 p m Monday Friday mountain time M S D W W W M S D P E R F O R M A N C E C O M 9 1 5 8 5 5 7...

Отзывы: