3

 

TECHNICAL SERVICE 

3.1

 

G

ENERAL DESCRIPTION

 

The TS

 

shall be provided by the staff acquainted with its composition, structure 

and operation features. 

In order to provide safe and reliable operation for the Product, the staff shall main-

tain technical service № 1 (hereinafter – TS-1) – semi-annual TS;

 

 

TS-1 shall be provided by the staff on the running equipment. 

3.2

 

S

AFETY FEATURES

 

While maintaining the TS, observe 4.2. 

3.3

 

M

AINTENANCE ROUTINE 

 

The list of works for all types of TS is given in table 6. Maintenance routine pro-

cedure is given in checklists, represented in tables 7, 8. 

Table 6 – List of works by TS types  

CL № 

Work  

Type of TS 

TS-1 

Visual check of the Product 

Test for the Product operability 

Note:  “+” – work is obligatory. 

Table 7 – Checklist № 1. Visual check of the Product 

To be done 

Routine 

Man-hours per 1 

Product 

Visually examine 
the Product  

1 check  completeness  and  appearance  of  the  Product; 
mechanical damage, paint defects must be absent; mark-
ing plates shall be present; legends are to be read easily. 
2 clean up the Product surfaces with clean cloth; 
3 remove  severe  contamination,  parts  of  corrosion,  oil 
spots  from  the  metal  surfaces  –  using  ethyl  alcohol, 
avoiding its penetration inside the Product; all surfaces 
clean dry by clean cloth and dry up; 
4 If varnish paint coating is damaged, polish it with sand 
paper, then clean with alcohol-soaked cloth, cover with 
varnish АК-113 and dry up.  

1 person  
5 mins 

Check reliability 
of cable and bus 
connection to the 
Product 

1 check that connectors and attaching screws are fas-
tened tight; provide further fastening if needed. 
2 check the cable integrity (mechanical damage shall 
be absent) within visibility  

1 person  
5 mins 

Содержание PS-103

Страница 1: ...v 0 7 NPK Morsvyazavtomatica LLC Power Supply unit PS 103 PS 103 20 Operating manual St Petersburg...

Страница 2: ...g 9 1 6 Packaging 9 2 USAGE OF THE PRODUCT 9 2 1 Operational constraints 9 2 2 Usage preparations 10 2 3 Usage of the product 11 3 TECHNICAL SERVICE 12 3 1 General description 12 3 2 Safety features 1...

Страница 3: ...Product PSU In addition to the instructions given in this document the safety regulations and rules applicable in the field shall be observed Only those who have read and understood this document and...

Страница 4: ...put voltage AC 50 60 Hz V 220 110 at option 10 Standby power from batteries V DC 24 Output voltage V DC 18 31 Rated load current 10 20 Rated power W output 190 400 consumed 240 450 Alarm output dry co...

Страница 5: ...Controls and indication The layout of the PSU s key functional elements controls and indication are rep resented in Figures 1 2 Figure 1 Functional elements controls and indication of PS 103 Figure 2...

Страница 6: ...ed to PS 103 and PS 103 20 terminals standby power is supplied from backup power sources to provide uninterruptible opera tion of the equipment connected to the PSU see figures 3 4 Caution The PSU sha...

Страница 7: ...r Terminal Description XS1 1 Alarm unit connection 2 3 XS5 1 24 V DC SB connection 2 0 V 3 Ground connection XS2 1 24 V DC to connect load 3 2 0 V 3 Ground connection XS3 1 24 V DC to connect load 2 2...

Страница 8: ...supplies power from SB to the external signaling unit Figure 4 Connection diagram of PS 103 20 Table 4 Description of connector terminals PS 103 20 Connector Terminal Description X9 1 Alarm unit conne...

Страница 9: ...t coating damage 1 5 MARKING AND SEALING The nameplates are located on the Product where the user can find the name serial number date of manufacturing weight protection degree output voltage and out...

Страница 10: ...g the units on the staff shall observe visually the cable integrity and initial position of the controls on the front panels check the absence of dust and dirt on the Product casing clean with a soft...

Страница 11: ...transfer piano type switch to ON position If you use PS 103 20 additionally transfer a circuit breaker inside the casing to ON position check load operation To switch the PSU off provide the followin...

Страница 12: ...rk is obligatory Table 7 Checklist 1 Visual check of the Product To be done Routine Man hours per 1 Product Visually examine the Product 1 check completeness and appearance of the Product mechanical d...

Страница 13: ...3 take the voltage on the load terminals 1 person 5 mins 3 4 PRESERVATION The Product and set of operational documents are stored in preserved condition in Man ufacturer s packaging boxes The time of...

Страница 14: ...if power supply of the repaired unit is on Installation aligning and repair works are PROHIBITED in the room where less than 2 people are present 4 3 CURRENT REPAIR OF THE PRODUCT The list of malfunct...

Страница 15: ...rage conditions 5 40 with the concentration of dust oil moisture and aggressive impu rities in the air within the required limits for the working areas of production facilities After storage or transp...

Страница 16: ...sportation in sealed and heated compartments sea transportation in dry service premises The units must be transported in compliance with transportation rules applicable for each means of transport Dur...

Страница 17: ...d an overage equipment unit to the manufacturer for its further disposal Proper disposal of Product components allows avoiding possible negative envi ronmental and health impacts and it also allows fo...

Страница 18: ...tica LLC Operating manual Page 18 ANNEX A MANDATORY OUTLINE AND INSTALLATION DIMENSIONS OF THE PRODUCT Figure A 1 Outline and installation dimensions of PS 103 Figure A 2 Outline and installation dime...

Отзывы: