REMOVING THE RESPIRATOR
DISCONNECTING THE FIREHAWK
PUSH-TO-CONNECT REGULATOR
1. Grasp top of regulator.
2. Push the release but-
tons and pull regulator
down and out of face-
piece adapter.
3. Disconnect the attach-
ment hose from the air
supply hose.
4. Open the bypass to vent system pressure. Close the
bypass.
5. Stow the regulator in the stand-by belt mount.
DISCONNECTING THE FIREHAWK
SLIDE-TO-CONNECT REGULATOR
1. Grasp top of regulator.
2. Push the release but-
tons and pull regulator
down and out of face-
piece adapter.
Note:
Regulator can hang on cover rail in a standby
mode.
3. Slide regulator up face-
piece cover rail until
regulator slide button is
free of rail.
4. Disconnect the attach-
ment hose from the air
supply hose.
5. Open the bypass to vent system pressure. Close the
bypass.
6. Stow the regulator in the stand-by belt mount.
13
TAL 903 (L) Rev. 1 - 10063148