OPERATION
DONNING THE RESPIRATOR
1. Remove the respirator from its storage location/case.
2. Check that the cylinder is fully pressurized.
DO NOT use a partially full cylinder. If the cylinder is
not full, escape service time is decreased.
DO NOT enter any area that requires an escape time
greater than the service life of the cylinder. Cylinder
life varies with the work rate of the individual and may
be shorter with heavy work loads. Failure to follow this
warning can result in serious personal injury or death.
3. Connect the air supply hoses to each other.
4. Connect air supply hoses to the air source.
DONNING THE CARRIER AND HARNESS, RIGHT HIP
VERSION
1. Hold the shoulder strap with the left hand. Slide shoul-
der strap over head so that the shoulder strap is posi-
tioned over the left shoulder and the cylinder is posi-
tioned on the right hip.
2. Adjust the shoulder
strap by pulling the
strap down.
Note:
The cylinder should be positioned at or just below
waist level.
3. Connect the waist belt buckle.
4. As necessary, slide the waist belt buckle toward the
cylinder to properly position the belt.
5. Adjust the waist strap
by pulling the strap to
the left.
6. Tuck in loose ends of shoulder strap and waist belt.
DONNING THE FACEPIECE WITH RUBBER HEAD
HARNESS
1. Loosen all harness
straps fully.
2. Insert chin into the
lower part of the face-
piece, then pull the
harness back over the
head.
3. Tighten the lower
straps first by pulling
them straight back, not
out.
8
TAL 903 (L) Rev. 1 - 10063148