DESCRIPTION

ed in a negative-pressure mode (with
blower off). This will cover use of the
respirator in the powered air-purifying
mode operation.

EXPOSURE LIMITS

A listing of acceptable exposure limits
from the following sources:

American Conference of
Governmental Industrial Hygienists
(ACGIH)

Occupational Safety and Health
Administration (OSHA)

National Institute for Occupational
Safety and Health (NIOSH)

American Industrial Hygiene
Association (AIHA)

Contact MSA at 1-800-MSA-2222 for
information.

Exposure Limits for Mixtures

The American Conference of Govern-
mental Industrial Hygienists (ACGIH)
publishes the following information to
determine the TLV of a mixture.

First determine the total concentration
of the chemical mixture (CMixture) from

the individual contaminant concentra-
tions (C1, C2, C3,…) using the following

formula:

CMixture = C1 + C2 + C3 + …

The TLV of the mixture is found by
using the following formula where T1,
T2, T3,… are the individual contaminant
TLVs and C1, C2, C3,… are the individ-
ual contaminant concentrations:

Only use these equations if the contam-
inants present are actually mixed. Some
substances do not mix and may be
present separately, for example, in
pockets or at different levels. In that
case, the lowest TLV of the substances
present must be used to determine the
appropriate respirator category for pro-
tection against all contaminants pres-
ent.

8

T

Mixture

=

C

Mixture

+

+

+ . . .

T

1

T

2

T

3

C

1

C

2

C

3

Содержание OptimAir MM 2K

Страница 1: ...r working hours See Approval Matrix Part No 818105 for NIOSH Approvals and Limitations THIS MANUAL INCLUDING THE WARNINGS AND CAUTIONS INSIDE MUST BE READ AND FOLLOWED CAREFULLY BY ALL PER SONS WHO US...

Страница 2: ...shall be selected fitted used and main tained in accordance with MSHA OSHA and other applicable regula tions N Never substitute modify add or omit parts Use only exact replace ment parts in the config...

Страница 3: ...in it according to the manu facturer s instructions Repairs must only be made by properly trained personnel LIMITATIONS The OptimAir MM 2K with OptiFilter Type HE filter cartridge or Type HE par ticul...

Страница 4: ...NIOSH approval plate P N 818105 to determine if this device can be used for escape from those concentrations 4 Do not use when appropriate exposure limit OSHA PEL NIOSH REL ACGIH TLV etc is not known...

Страница 5: ...n an occupational setting MUST be used in accordance with a complete respiratory pro tection program as required by OSHA which includes proper selection training fit testing and fit checking Detailed...

Страница 6: ...TAL 0110 L Rev 8 10020949 NOTES 6...

Страница 7: ...if a leak occurs air will flow from inside the facepiece to the outside air This is referred to as positive pressure Air flow also provides wearer comfort The rechargeable NiMH battery pack supplies 4...

Страница 8: ...ACGIH publishes the following information to determine the TLV of a mixture First determine the total concentration of the chemical mixture CMixture from the individual contaminant concentra tions C1...

Страница 9: ...the sound of the motor If the impeller binds or rattles or if air output is reduced the entire motor blower must be replaced CHARGING THE BATTERY PACK The battery pack must be fully charged before th...

Страница 10: ...be Red When the LED is Green the bat tery is fully charged The battery can stay connected to the charger until it is needed If the LED is Amber the bat tery is not at the proper temperature The charg...

Страница 11: ...two notch es on the coupling nut into the facepiece 3 If attached unthread the filter from the motor blower assembly 4 Check that there is a gasket in the motor blower housing The gas ket is necessary...

Страница 12: ...TAL 0110 L Rev 8 10020949 NOTES 12...

Страница 13: ...FAILURE TO FOLLOW THE ABOVE WARNINGS CAN RESULT IN SERI OUS PERSONAL INJURY OR DEATH DONNING THE SUPPORT BELT AND BATTERY PACK 1 Thread the belt through the belt loops on the battery pack 2 Don the su...

Страница 14: ...the length of the two top straps To adjust the top straps a Remove the strap from the fas tener button by pulling the loose end of the strap away from the fastener button b Move the slide away from th...

Страница 15: ...k over head 4 Pull the back of harness down ward until cen tered at the back of the head 5 Tighten the two lower straps first by pulling them straight back not out Tighten the facepiece until the mask...

Страница 16: ...ve a mous tache beard gross sideburns or other physical characteristics that interfere with the face to facepiece seal see ANSI Z88 2 If the face piece does not seal against your face non respirable a...

Страница 17: ...an when the motor blower is supplying air to the facepiece REMOVING THE RESPIRATOR 1 Return to fresh air and clean the outer surfaces of the respirator before removing the facepiece 2 Turn the power s...

Страница 18: ...TAL 0110 L Rev 8 10020949 NOTES 18...

Страница 19: ...ceable replace the filter 1 Replacing the filter The filter is not designed to be cleaned and reused Do not try to clean the filter You may damage the inside of the filter and eliminate res piratory p...

Страница 20: ...touch the contaminant in handling the respirator or its parts Use equip ment designed to protect you from the specific contaminant Failure to follow this warning can result in serous personal injury o...

Страница 21: ...ay deteriorate the rubber 5 Use a damp cloth or sponge satu rated with Confidence Plus cleaning solution or an equivalent solution to wipe the motor blower and battery pack housing and battery cable c...

Страница 22: ...TAL 0110 L Rev 8 10020949 NOTES 22...

Страница 23: ...g delivered to offset self discharge Amber Charge Pending Battery Temperature is outside the charge range If the battery is too hot charge will not begin until temperature falls If temperature is too...

Страница 24: ...uit Voltage across the Switch 1 Set the multimeter to measure volt age 2 Turn the switch on the battery pack to the OFF position 3 Place the positive probe on pin 1 and the negative lead on to pin 2 4...

Страница 25: ...good battery pack as deter mined by the previous tests fully charge the battery until a full charge is achieved Testing the Flow of the motor blower 1 Assemble the motor blower to the battery pack 2 A...

Страница 26: ...rge Failure Red Flashing LED Change Battery and Recharge Successful Charge Green LED Charge Failure Red Flashing LED Replace Charger Replace Original Battery Pack Mtr Blower Resistance Test Mtr Blower...

Страница 27: ...of nosecup is over tab of inhalation valve housing 4 Stretch nosecup around lip on inhalation valve housing ensuring nosecup is in place SPECTACLE KIT Spectacle kits are available for the Ultravue P N...

Страница 28: ...ist an dpull the spark cover off 6 Check the spark cover before each use to ensure no sparks have creat ed holes o warped the part If holes are created or the part is warped relace the spakr cover wit...

Страница 29: ...TAL 0110 L Rev 8 10020949 29...

Страница 30: ...TAL 0110 L Rev 8 10020949 30 a 804805 804804 804810 805011 804820 495188 495189 10051290 804831 10116528 Door Component Housing ClearCommand 19a...

Страница 31: ...TAL 0110 L Rev 8 10020949 31 20...

Страница 32: ......

Отзывы: