The device has four gas alarms:
- HIGH Alarm
- LOW Alarm
- STEL Alarm
- TWA Alarm
If the gas concentration reaches or exceeds the alarm set point, the device:
- backlight turns on
- provides a vibrating alarm
- displays and flashes the Alarm symbol and either the Minimum icon
[LOW alarm] or the Maximum [PEAK] icon [HIGH alarm]
- enters an alarm state.
2.10 Monitoring Oxygen Concentration
The device monitors the oxygen concentration in ambient air. The alarm set points
can be set to activate on two different conditions:
- Enriched - oxygen concentration > 20.8 vol. % or
- Deficient - oxygen concentration < 19.5 vol. %.
When the alarm set point is reached for either of the above conditions:
- an alarm sounds
- alarm LEDs flash
- a vibrating alarm triggers
- device displays and flashes the Alarm icon and either the Minimum icon [En-
riched alarm] or the Maximum icon [Deficient alarm] [
chapter 2.3] along with
the corresponding oxygen concentration.
Attention!
If an alarm is triggered while using the device, leave the area
immediately.
Remaining in the area under such circumstances can cause serious
personal injury or death.