MSA
Operation
ALTAIR 4X
32
GB
3.4
Device Setup
The setup menus can be accessed only when the device is turned on while pressing
and holding the
button.
This mode can only be activated at device turn-on.
The operation is as follows:
(1) Press and hold the
button while turning the device on.
Use the
and
buttons to enter the setup password.
The default password is "672".
(2) Press
ON/OFF
button to enter the setup menus.
Incorrect password: device enters the Measure mode.
Correct password: device continues/beeps three times.
In the Setup mode:
- Press the
ON/OFF
button to store chosen value or go to the next page.
- Press
button to increase values by one or toggle a selection on or off.
- Press and hold
button to increase values by 10.
- Press
button to decrease values by one or toggle a selection on or off.
- Press and hold
button to decrease values by 10.
The following options are available by pressing the
and
buttons:
- Sensor Setup [
SENSOR SETUP
]
- Calibration Setup [
CAL SETUP
]
- Alarm Setup [
ALARM SETUP
]
- Setup Time and Date [
TIME SET
]
-
EXIT
The password can be changed through the MSA Link software.