19
Preparing for Use
G1 Powered Air-Purifying Respirator (PAPR)
US
6.2
Installing the Battery
WARNING!
Do NOT use any battery that shows signs of damage, bulging, swelling, disfigurement, or liquid in the
plastic wrap.
Failure to obey this warning can result in serious injury or death.
6.2.1 Single-Use (Li-SO
2
) Batteries
WARNING!
Do NOT let single-use (Li-SO
2
) batteries fall to the ground or be damaged in any way that can cause
a rupture. Single-use (Li-SO
2
) batteries contain pressurized sulfur dioxide gas, which is toxic.
If you smell an odor like vinegar or rotten eggs from the single-use (Li-SO
2
) battery, there is possibly
a leakage of battery gas. Put on protective gloves before you touch the battery. Remove the battery.
Obey the instructions in Section 11.1 "Discarding Single-Use (Li-SO
) Batteries" to discard the
battery. Obey the instructions in Section 6.2 "Installing the Battery" to install a new battery.
Failure to obey these warnings can result in serious injury or death.
Use the black battery cap assembly supplied with the blower assembly. Each battery cap assembly
has a retaining lanyard to prevent loss of cap.
(5) Install the keeper loop on the belt.
(6) Install the male buckle on the belt.