MS Sedco ID20 Скачать руководство пользователя страница 3

ID20

Industrial Door Microwave Motion Sensor 

INSTALLATION INSTRUCTIONS

Page 3

(/MANU) ID20v0913

FIGURE 1

Mounting Bracket

Base

Cover

Wire Fitting

Hex Head 

Cover

Screw (2)

Hex Head Cover

Screw (2)

1/4-20 Hinge Bolt

ID20 Housing

8701 Castle Park Drive 

 Indianapolis, Indiana 46256

Telephone: (317) 842-2545 

 www.mssedco.com 

 [email protected]

Содержание ID20

Страница 1: ...terminal block located on the printed circuit board Fig 2 NOTICE Operating voltage is 12V to 24V AC or DC and should be applied through the transformer supplied with the unit Allow the device 10 seconds to warm up once power is applied WARNING Do Not ground one side of the secondary of the supply transformer Circuit ground of the unit is electrically connected to the housing Grounding one side of ...

Страница 2: ...cket predrilled slotted Temperature 35 F to 165 F 35 C to 74 C Weight 3 5 lbs 1 6 kg Size 7 x 4 x 4 17 8cm x 10 2cm x 10 2cm Color Enclosure Aluminum black powder coat finish Section 5 Warranty MS SEDCO guarantees this product to be free from manufacturing defects for one year from date of installation Unless MS SEDCO is notified of the date of installation the warranty will be in effect for one y...

Страница 3: ...UCTIONS Page 3 MANU ID20v0913 FIGURE 1 Mounting Bracket Base Cover Wire Fitting Hex Head Cover Screw 2 Hex Head Cover Screw 2 1 4 20 Hinge Bolt ID20 Housing 8701 Castle Park Drive Indianapolis Indiana 46256 Telephone 317 842 2545 www mssedco com custsvc mssedco com ...

Страница 4: ...y Connections 4 Normally Open N O 5 Common 6 Normally Closed N C NOTE Relay is with power applied and unit setup for Failsafe operation Time Delay Adjustment 0 to 5 seconds Clockwise to increase counterclockwise to decrease NOTES 1 The LED Indicator is illuminated whenever the Relay is activated 2 The Range Adjustment allows the Pattern Distance to be varied for each individual installation 3 The ...