MS Schippers 4508560 Скачать руководство пользователя страница 12

12 

 

4. Place Reverse Osmose Filter in the Reverse Osmose holder 
 

 

 

 

5. Place the Harsbed filter in the white holder on the back of the device 
 

 

 
6. Connect the 10 mm hose (the thickest one) to the water supply. 

INPUT

  

 
7. The 8 mm hose that comes from the UV-filter at the back of the device. 

DEMI WATER

 

 
8. The 8 mm hose that comes from the top of the device = 

WASTE WATER

 

 
9. Turn the power and water on. 
 
10. When the pressure is high enough the device starts to produce 

DEMI WATER

. When the 

pressure drops the device turns off automatically and will also start again when the pressure 
reaches the required level. 
 
After a double check if all filters are in place, the system can be plugged in and switched on 
with the on / off switch. 
As soon as the water pressure is high enough the device will come into action and will start 
to purify water. 
 

Note

: The produced water is not suitable for human consumption!

Содержание 4508560

Страница 1: ...1 MS Reverse Osmosis 30 4508560 NL MS Reverse Osmosis 30 Gebruiksaanwijzing 2 EN MS Reverse Osmosis 30 Manual 9 4508560 25 07 2014 F ...

Страница 2: ...er na een uitgebreide voorfiltratie door het RO membraam perst Hierdoor wordt een hogere capaciteit verkregen in vergelijking tot apparaten die op waterleidingdruk werken Afhankelijk van de kwaliteit van het ingangswater zal de RO 30 een capaciteit hebben van ca 30 liter per uur Uitleg van het 6 staps systeem Stap 1 Polypropylene filter 8809670 filtert de vaste delen uit het water met een grootte ...

Страница 3: ... van dit soort filters is bijna niet vooraf te bepalen daar dit sterk afhankelijk is van de kwaliteit van het toevoerwater De hars in het DI filter wordt vervangen zodra deze is verzadigd Verzadiging kan ook optreden gedurende stilstand Het is daarom aan te raden deze filter iedere 3 5 maanden te vervangen om eventuele risico s uit te sluiten Stap 6 UV lamp Gedurende deze laatste stap worden de no...

Страница 4: ...e van het apparaat 8809670 Polypropyleen PPF filter 5 micron 2 Plaats filter 2 in de blauwe houder in het midden van het apparaat 8809671 Actief koolfilter UDF 3 Plaats filter 2 in de blauwe houder aan de rechtse zijde van het apparaat 8809672 Polypropyleen PPF filter 1 micron ...

Страница 5: ...top de stekker in het stopcontact en draai de kraan open 10 Wanneer de druk hoog genoeg is begint het apparaat DEMI WATER te produceren Als de druk daalt schakelt het apparaat automatisch uit en zal ook opnieuw starten wanneer de druk het gewenste niveau weer heeft bereikt Na controle of alle filters daadwerkelijk aanwezig zijn in het apparaat plaatst men de stekker in het stopcontact en kan het a...

Страница 6: ...6 Schematische weergave van het systeem ...

Страница 7: ...onderwerpen kan de zogenaamde back flush functie ingeschakeld worden op de display door op de 3e toets te drukken Als deze functie geactiveerd word zal de melding strong back flushing in het display zichtbaar zijn Gedurende deze functie wordt enkel het RO membraam gereinigd Na ca 5 minuten zal het apparaat automatisch weer in de normale modus terecht komen en de filtratie hervatten De geleidbaarhe...

Страница 8: ...RO 30 8809680 Hoge druk klep tbv MS RO 30 8809681 Bepalingen MS Schippers aanvaardt geen verantwoordelijkheid voor fouten in dit document alsmede voor enige directe of indirecte schade vervolgschade van welke aard dan ook ontstaan uit of verband houdende met de aflevering het functioneren of het gebruik van dit document MS Schippers behoudt zich het recht voor op ieder moment zonder voorafgaande k...

Страница 9: ...n extensive pre filtration through the RO membrane by adding a booster pump a higher capacity is reached when compared with RO systems that use the pressure available in standard tap water Depending on the impurities present in the raw unfiltered water the MS RO 30 can reach a capacity of approximately 30 litres per hour Explanation of the 6 step system Step 1 Poly propylene filter 8809670 filters...

Страница 10: ...micro Siemens values measured will be extremely low The precise life span of all filters isn t easy to predict since this is directly determinate by the quality of the unfiltered inlet water The resin of the DI filter has to be replaced once this is satiated Satiation can also occur during standstill of the system it is recommended to replace the mixed hars bed filter every 3 5 months to avoid ris...

Страница 11: ...acing filters 1 Place filter 1 in the blue holder on the left side of the device 2 Place filter 2 in the blue holder in the middle of the device 3 Place filter 3 in the blue holder on the right of the device ...

Страница 12: ...ce WASTE WATER 9 Turn the power and water on 10 When the pressure is high enough the device starts to produce DEMI WATER When the pressure drops the device turns off automatically and will also start again when the pressure reaches the required level After a double check if all filters are in place the system can be plugged in and switched on with the on off switch As soon as the water pressure is...

Страница 13: ...13 Schematic overview of the system ...

Страница 14: ...ive the RO membrane a separate back flush this back flush can be switched on by pressing the 3th button on the display When this function is activated strong back flushing is visible in the display During the back flushing modus ONLY the RO membrane is maintained After abt 5 minutes the system will return to the normal operating modus automatically and will continue the filtration process Conducti...

Страница 15: ...re valve for MS RO 30 8809682 Operation Valve for MS RO 30 8809683 temperature conductivity probe for MS RO 30 8809684 Tubing 9 5 mm for MS RO 30 8809685 Tubing 6 mm for MS RO 30 Provisions MS Schippers assumes no responsibility for errors contained herein or for any direct or indirect damages or consequential damages of any nature whatsoever arising from or in connection with provision function o...

Страница 16: ...16 ...

Отзывы: