Installation Instructions and Owner’s Manual

Universal Unvented Room Heater

Attaching to Wall Anchor: 

This way allows you to attach mounting bracket to hollow 
walls (wall areas between studs) or to solid walls (concrete 
or masonry).
Decide which way best suits your needs. Either method will 
provide a secure hold for the mounting bracket.

1.  Tape mounting bracket to wall where heater will 

be located. Make sure mounting bracket is level. 
For wall stud mounting locate one end of the 
mounting bracket over a wall stud.

WARNING: Maintain minimum clearances shown in figure 

7. If you can, provide greater clearances from the floor 

and joining wall. 

2.  Mark screw locations on wall (see figure 7).

3.  Remove tape and mount bracket from wall.

A

djoining W

all

18” Min.

See clearance 
specs on Pg 3

16” (Lg)
12-9/64” (Sm)

Mark mounting hole locations and 
drill holes where indicated. Allow for 
minimum clearances

Figure 7

Attaching to Wall Stud:

For attaching mounting bracket to wall studs

1. 

Drill holes at marked locations using 9/64” drill bit.

2. 

Place mounting bracket onto wall. Line up holes on 
each end of bracket with hole drilled in wall.

3.  Insert mounting screws through bracket and into 

wall studs.

4.  Tighten screws until mounting bracket is firmly 

fastened to wall studs.

Attaching to Wall using Anchor:

For attaching mounting bracket to hollow walls (wall areas 
between studs) or solid walls (concrete or masonry)
Note: Wall anchors, mounting screws, and spacer are in 
hardware package. The hardware package is provided with 
heater. 

1. 

Drill holes at marked locations using 5/16” drill bit. 
For solid walls (concrete or masonry), drill at least 1” 

deep.

2. Fold wall anchor as shown in figure 8 below. 

3. Insert wall anchor (wings 

first) into hole. Tap anchor 
flush to wall.

4. 

For thin walls (1/2” or less) 

insert red key into wall 
anchor. 

5. Place mounting bracket onto wall. Line up holes on 

each end of bracket with wall anchors.

6. Insert mounting screws through bracket and into 

wall anchors.

7. 

Tighten screws until mounting bracket is firmly 
fastened to wall.

Placing Heater on Mounting Bracket

1. Locate two horizontal slots on back pane of heater 

(see figure 9).

2. 

Place heater onto mounting bracket. Slide horizontal 

slots onto stand-out tabs on mounting bracket.

Horizontal Slots

Mounting Bracket 
mounted to wall

Figure 9

Installing Bottom Mounting Screws

1. Locate two bottom mounting holes. These holes are 

near bottom on back panel of heater (see figure 10).

Screw  
hole

Screw  
hole

Figure 10

 

2. 

Mark screws locations on wall.

3. Remove heater from mounting bracket.
4. If installing bottom mounting screw into hollow 

or solid wall, install wall anchors. Follow steps 1 
through 4 under Attaching to Wall using Anchor. If 
installing bottom mounting screw into wall stud, drill 

holes at marked locations using 9/64” drill bit.

5. 

Re-place heater onto mounting bracket.

6. Place spacers between bottom mounting holes and 

wall anchor or drilled hole.

7. 

Hold spacer in place with one hand. With the other 
hand, insert mounting screw through bottom 
mounting hole and spacer. Place tip of screw in 
opening of wall anchor or drilled hole.

8. 

Tighten both screws until heater is firmly secured to 
wall. Do not over tighten.

Note: Do not re-place front panel at this time. 

Replace front panel after making gas connections and 
checking for leaks.

Figure 8.

Содержание MHVFDF10BF

Страница 1: ...the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier T...

Страница 2: ...including benzene which is known to the state of California to cause cancer and cause birth defects or other reproductive harm for more information go to www P65Warnings ca gov Due to high temperature...

Страница 3: ...servicing Only a qualified service person should service and repair heater 6 Do not run heater Where flammable liquids or vapors are used or stored During dusty conditions 7 Before using furniture po...

Страница 4: ...s Code or applicable local codes 3 Add the Btu hr of all the fuel burning appliances in the space such as Vent free heater Gas water heater Gas furnace Vented gas heater Gas fireplace logs and Other g...

Страница 5: ...ion and Ventilation for required size of ventilation grills or ducts WARNING Rework worksheet adding the space of the adjoining unconfined space The combined space must have enough fresh air to supply...

Страница 6: ...floor Locate heater where moving vehicle will not hit it CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next to vinyl or cloth...

Страница 7: ...using 5 16 drill bit For solid walls concrete or masonry drill at least 1 deep 2 Fold wall anchor as shown in figure 8 below 3 Insert wall anchor wings first into hole Tap anchor flush to wall 4 For t...

Страница 8: ...ust connect heater to gas supply Follow all local codes WARNING This appliance requires a 3 8 NPT National Pipe Thread inlet connection to the pressure regulator Use of floor mounting feet will requir...

Страница 9: ...opane LP supply valve 3 Check all joints from the propane LP supply valve to equipment shutoff valve see figure 14 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 4 Co...

Страница 10: ...supplier for repairs Until repairs are made light pilot with match 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob If pilot does not stay lit r...

Страница 11: ...he can you could damage the burner or pilot assembly In addition the directions below should also be followed 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes...

Страница 12: ...ose at control valve Hand tighten thermocouple nut until snug and then tighten 1 4 turn more Pilot flame not touching thermocouple which allows thermocouple to cool causing pilot flame to go out This...

Страница 13: ...clearances see Figure 4 page 6 Dirty or partially clogged burner orifice Clean burner orifice see Cleaning and Maintenance on page 1 1 or replace burner orifice White powder residue forming within bu...

Страница 14: ...e purchased at any Mr Heater Products local dealer or direct from the factory FOR INFORMATION REGARDING SERVICE Please call Toll Free 866 447 2194 WWW HEATSTARBYENERCO COM Our office hours are 8 00 AM...

Отзывы: