MrHeater MHVFBF10NGT Скачать руководство пользователя страница 3

3

Operating Instructions and Owner’s Manual

Mr. Heater | Unvented Natural Gas Fired Room Heater

Specifications

MODEL

MHVFRD10NGT / MHVFBF10NGT

BTU (Available) 

10,000 

Type of Gas 

Natural Gas Only 

Ignition 

Battery Igniter (1-AAA)

Manifold Pressure 

4.5 Inches of Water  

Inlet Gas Pressure (Maximum) 

14 Inches of Water 

Inlet Gas Pressure (Minimum) 

7 Inches of Water 

Thermostatic Control 

Yes

Clearances: Inches (mm)

 Top 

36” (91.4 cm) 

 Sides 

10” (25.4 cm) 

  Floor (min. to top of carpet) 

3” (7.6 cm) 

  Fabric / flammable objects 

36” (91.4 cm) 

CONTENTS

2    

Warnings

3    

Specifications

3    

Precautions

4    

Installation

9    

Operation

Lighting

Shutdown

11    

Maintenance

12    

Troubleshooting

16

   Parts List

20   

Ordering Parts/Warranty

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

PRECA

UTIONS

PRECAUTIONS:

1.  Either of the 10,000 BTU (2931 W) 

units (the MHVFRD10NGT or the 
MHVFBF10NGT) may be installed in 
a bedroom, but shall not be installed 
in a bathroom or any place where a 
strong wind would shut down the 
appliance.

2.  This heater needs outside ventilation 

air to run properly. The Oxygen 
Depletion Sensor (ODS) safety shutoff 
system shuts down the heater if not 
enough fresh air is available. See Fresh 
Air for Combustion and Ventilation, 
page 4.

3.  Keep all air openings in heater clear, 

free of debris or any blockage. This 
will ensure that enough air for proper 
combustion enters the heater.

4.  If heater shuts off, do not relight 

until you provide fresh, outside air. If 
heater keeps shutting off, it requires 
servicing.

5.  Turn off and let cool before servicing. 

Only a qualified service person should 
service and repair heater.

6.  Do not run heater:
•  Where flammable liquids or vapors are 

used or stored

•  During dusty conditions.
7.  Before using furniture polish, wax, 

carpet cleaner or similar products, turn 
heater off. If heated the vapors from 
these products may create a white 

powder residue within burner box or 
on adjacent walls or furniture.

8.  Do not use heater if any part has 

been underwater. Immediately call a 
qualified service technician to inspect 
the room heater and to replace any 
part of the control system and any gas 
control which has been underwater.

9.  Operating heater above elevations 

of 4,500 feet could cause pilot/ODS 
to shutdown heater.

Carbon Monoxide Poisoning:

Early signs of carbon monoxide poisoning 
resemble the flu, with headaches, 
dizziness, or nausea. If you have these 
signs, the heater may not be working 
properly. Get fresh air at once! Have 
heater serviced. Some people are more 
affected by carbon monoxide than others. 
These include pregnant women, persons 
with heart or lung disease or anemia, 
those under the influence of alcohol, and 
those at high altitudes.

Natural Gas: 

Natural gas is odorless. An odor making 
agent is added to natural gas. The odor 
helps you detect a natural gas leak. 
However, the odor added to the gas can 
fade. Gas may be present even though 
no odor exists. Make certain you read 
and understand all warnings. Keep this 
manual for reference.  
It is your guide to safe and proper 
operation of this heater.

Safety Device

This heater has a pilot with an Oxygen 
Depletion Sensor (ODS) safety shut off 
system. The ODS/pilot shuts off the 
heater if there is not enough fresh air. 

Ignition System/Battery 
Installation

PIEZO: 

The heater is equipped with an 

electronic manual ignitor. This system 
requires no matches, batteries, or other 
source to light heater but does require 
one AAA battery to operate ignitor. 
To install or replace battery unscrew the 
ignitor cap (red button), insert battery 
positive (+) terminal up and replace cap. 
(AAA Battery included).

Thermostatic Control

These heaters have a control valve with 
a thermostat sensing bulb. This results 
in the greatest heater comfort and may 
result in lower fuel bills.

**Operating heater above elevations of 4,500 feet could cause pilot/ODS to shutdown heat

er.**

SOCIAL MEDIA

In order to provide the best service possible Mr. Heater is now giving you more 

ways to get in touch with us:
WEBSITE:   Mr. Heater’s full line of product are now at:

 www.mrheater.com

 FACEBOOK: Find us on Facebook 

 

 TWITTER: Find us on twitter 

 YouTube: There are now informational videos on Youtube.

DANGER: C

arbon monoxide 

poisoning may lead to death. 

Содержание MHVFBF10NGT

Страница 1: ...e or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch...

Страница 2: ...rating the heater Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent...

Страница 3: ...been underwater Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been underwater 9 Operating heat...

Страница 4: ...lings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and 2 Weather stripping has...

Страница 5: ...onfined space You will need no additional fresh air ventilation Ventilation Air Ventilation from Inside Building This fresh air would come from an adjoining unconfined space When ventilation to an adj...

Страница 6: ...s are 16 inches apart Attach mounting bracket to wall in one of two following ways 1 Attach to wall studs 2 Attach to wall anchor Decide which way best suits your needs Either method will provide a se...

Страница 7: ...rk screws locations on wall 3 Remove heater from mounting bracket 4 If installing bottom mounting screw into hollow or solid wall install wall anchors Follow steps 1 through 4 under Attaching to Wall...

Страница 8: ...pliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ps...

Страница 9: ...ctly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Shut...

Страница 10: ...ilot Position CAUTION Do not try to adjust heating level by using equipment shutoff valve To Turn Off Gas To Appliance SHUTTING OFF HEATER 1 Turn off equipment shutoff valve 2 Turn control knob clockw...

Страница 11: ...s vacuum cleaner pressurized air or small soft bristled brush to clean CLEANING BURNER PILOT AIR HOLE INLET We recommend that you clean the unit every 2 500 hours of operation or every three months We...

Страница 12: ...l the fire department SYMPTOM SYMPTOM When ignitor button is pressed in there is a spark at the ODS pilot but no ignition When igniter button is pressed in there is no spark at pilot CAUSE CAUSE REMED...

Страница 13: ...as regulator 7 Thermocouple connection loose at control valve 7 Hand tighten thermocouple nut until snug and then tighten 1 4 turn more 8 Pilot flame not touching thermocouple which allows thermocoupl...

Страница 14: ...lly clogged 3 Clean ODS pilot see Cleaning and Maintenance page 11 1 Gas leak See WARNING statement at top of page 12 1 Locate and correct all leaks see Checking Gas Connections page 9 2 Control valve...

Страница 15: ...o Fresh Air for Combustion and Ventilation on pages 3 5 REMEDY SYMPTOM Heater produces a clicking ticking noise just after burner is lit or shut off CAUSE 1 Metal expanding while heating or contractin...

Страница 16: ...01 Orifice 1 9 80084 Regulator 1 10 80055 Regulator Mounting Bracket 1 11 80058 Floor Mounting Feet Beige 1 Item Part No Description 80214 Floor Mounting Feet White 1 12 NA Regulator Connection 1 13 8...

Страница 17: ...84 Regulator 1 7 80055 Regulator Mounting Bracket 1 8 80058 Floor Mounting Feet Beige 1 80214 Floor Mounting Feet White 1 Item Part No Description 9 NA Regulator Connection 1 10 80036 Wall Mounting Br...

Страница 18: ...Natual Gas Fired Room Heater Operating Instructions and Owner s Manual NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDE...

Страница 19: ...ons and Owner s Manual Mr Heater Unvented Natural Gas Fired Room Heater NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDE...

Страница 20: ...AM 5 00 PM EST Monday through Friday Please include the model number date of purchase and description of problem in all communication LIMITED WARRANTY Mr Heater Inc warrants its heaters and accessorie...

Отзывы: