MrHeater MHVFBF10NGT Скачать руководство пользователя страница 16

16

Mr. Heater | Unvented Natual Gas Fired Room Heater

Operating Instructions and Owner’s Manual

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

PAR

TS LIST

Mr. Heater • Unvented Natural Gas Fired Room Heater • Model # MHVFBF10NGT

Item

Part No.

Description

1

80040

Wire Guard

1

2

80051

Front Panel (Beige)

1

80201

Front Panel (White)

1

4

80024

Reflector

1

5

80026

Reflector Back Panel

1

6

80057

ODS Pilot Assembly w/ 
Thermocouple (NG)

1

7

80017

Burner Assembly

1

8

80009-01 Orifice

1

9

80084

Regulator

1

10

80055

Regulator Mounting Bracket

1

11

80058

Floor Mounting Feet (Beige)

1

Item

Part No.

Description

80214

Floor Mounting Feet (White)

1

12

NA

Regulator Connection

1

13

80036

Wall Mounting Bracket

1

14

80052

Back Panel (Beige)

1

80177

Back Panel (White)

1

15

80010

Thermostat Valve Mounting Bracket 1

16

70640

Thermostat Valve

1

17

80176

Igniter Module

1

18

80185

Curved Heat Shield

1

19

80014

Igniter Wire

1

20

80184

Igniter Module Mounting Bracket

1

**

70342

Hardware Kit (not shown)

1

WARNING: 

Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with 

this heater may result in property damage or personal injury.

1

2

4

5

6

7

8

9 10

11

12

13

14

15

16

17

19

20

18

Содержание MHVFBF10NGT

Страница 1: ...e or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch...

Страница 2: ...rating the heater Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent...

Страница 3: ...been underwater Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been underwater 9 Operating heat...

Страница 4: ...lings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and 2 Weather stripping has...

Страница 5: ...onfined space You will need no additional fresh air ventilation Ventilation Air Ventilation from Inside Building This fresh air would come from an adjoining unconfined space When ventilation to an adj...

Страница 6: ...s are 16 inches apart Attach mounting bracket to wall in one of two following ways 1 Attach to wall studs 2 Attach to wall anchor Decide which way best suits your needs Either method will provide a se...

Страница 7: ...rk screws locations on wall 3 Remove heater from mounting bracket 4 If installing bottom mounting screw into hollow or solid wall install wall anchors Follow steps 1 through 4 under Attaching to Wall...

Страница 8: ...pliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ps...

Страница 9: ...ctly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Shut...

Страница 10: ...ilot Position CAUTION Do not try to adjust heating level by using equipment shutoff valve To Turn Off Gas To Appliance SHUTTING OFF HEATER 1 Turn off equipment shutoff valve 2 Turn control knob clockw...

Страница 11: ...s vacuum cleaner pressurized air or small soft bristled brush to clean CLEANING BURNER PILOT AIR HOLE INLET We recommend that you clean the unit every 2 500 hours of operation or every three months We...

Страница 12: ...l the fire department SYMPTOM SYMPTOM When ignitor button is pressed in there is a spark at the ODS pilot but no ignition When igniter button is pressed in there is no spark at pilot CAUSE CAUSE REMED...

Страница 13: ...as regulator 7 Thermocouple connection loose at control valve 7 Hand tighten thermocouple nut until snug and then tighten 1 4 turn more 8 Pilot flame not touching thermocouple which allows thermocoupl...

Страница 14: ...lly clogged 3 Clean ODS pilot see Cleaning and Maintenance page 11 1 Gas leak See WARNING statement at top of page 12 1 Locate and correct all leaks see Checking Gas Connections page 9 2 Control valve...

Страница 15: ...o Fresh Air for Combustion and Ventilation on pages 3 5 REMEDY SYMPTOM Heater produces a clicking ticking noise just after burner is lit or shut off CAUSE 1 Metal expanding while heating or contractin...

Страница 16: ...01 Orifice 1 9 80084 Regulator 1 10 80055 Regulator Mounting Bracket 1 11 80058 Floor Mounting Feet Beige 1 Item Part No Description 80214 Floor Mounting Feet White 1 12 NA Regulator Connection 1 13 8...

Страница 17: ...84 Regulator 1 7 80055 Regulator Mounting Bracket 1 8 80058 Floor Mounting Feet Beige 1 80214 Floor Mounting Feet White 1 Item Part No Description 9 NA Regulator Connection 1 10 80036 Wall Mounting Br...

Страница 18: ...Natual Gas Fired Room Heater Operating Instructions and Owner s Manual NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDE...

Страница 19: ...ons and Owner s Manual Mr Heater Unvented Natural Gas Fired Room Heater NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDE...

Страница 20: ...AM 5 00 PM EST Monday through Friday Please include the model number date of purchase and description of problem in all communication LIMITED WARRANTY Mr Heater Inc warrants its heaters and accessorie...

Отзывы: