MRC PAM-9212SD Скачать руководство пользователя страница 1

SD card real time Data Recorder
200 mbar, differential manometer

PITOT TUBE ANEMOMETER

Model : PAM-9212SD

Your purchase of this
PITOT TUBE ANEMOMETER  
with SD CARD DATA LOGGER
marks a step forward for you
into the field of
precision measurement.
Although this meter a
complex and delicate
instrument, its durable
structure will allow
many years of use if
proper operating
techniques are
developed. Please read
the following
instructions carefully
and always keep this
manual within easy
reach.

 OPERATION MANUAL

PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Hagavish st. Israel 58817  Tel: 972 3 5595252, Fax: 972 3 5594529   

[email protected]

 

MRC.

5

.

22

Содержание PAM-9212SD

Страница 1: ... precision measurement Although this meter a complex and delicate instrument its durable structure will allow many years of use if proper operating techniques are developed Please read the following instructions carefully and always keep this manual within easy reach OPERATION MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 mrc...

Страница 2: ...me and sampling time information 14 5 5 SD Card Data structure 14 6 Saving data from the SD card to the computer EXCEL software 16 7 ADVANCED SETTING 18 7 1 Set clock time Year Month Date Hour Minute Second 18 7 2 Set sampling time Hour Minute Second 19 7 3 Auto power OFF management 19 7 4 Set beeper sound ON OFF 20 7 5 Decimal point of SD card setting 20 7 6 SD memory card Format 21 7 7 Air densi...

Страница 3: ...ro value Microprocessor circuit assures maximum possible accuracy provides special functions and features Super large LCD display with contrast adjustment for best viewing angle setup extra software after execute datalogger just take away the SD card from the meter and plug in the SD card into the computer it can download the all the measured value with the time information year month date hour mi...

Страница 4: ... sensor Used for dry non corrosive and non ionic air and gas only Liquid is prohibited Datalogger Auto 1 sec to 8 Hour 59 Minute 59 sec Sampling Time Sampling time can set to 1 second Setting range but memory data may loss Manual Push the data logger button once will save data one time Set the sampling time to 0 second Manual mode can also select the 1 to 99 position Location no Data error no 0 1 ...

Страница 5: ...e or heavy duty DC 1 5 V battery UM3 AA x 6 PCs or equivalent AC DC power adapter is optional DC 9V adapter input AC DC power adapter is optional Power Current Normal operation w o SD card save data and LCD Backlight is OFF Approx DC 7 mA When SD card save the data and LCD Backlight is OFF Approx DC 25 mA AC DC power adapter is optional If LCD backlight on the power consumption will increase appro...

Страница 6: ...Accuracy m s 4 1 to 100 0 m s 0 1 m s 3 a reading Km h 14 7 to 360 0 km h 0 1 Km h or Mile h 9 1 to 223 7 mph 0 1 mph 1 a mph full scale Knot 7 9 to 194 3 knot 0 1 Knot Air density Ft min 81 19685 ft min 1 Ft min 1 200 a 0 1 m s 0 3 km h 0 2 mile h 0 2 knot 20 ft min Note m s meters per second km h kilometers per hour ft min feet per minute knot nautical miles per hour mile h miles per hour intern...

Страница 7: ... h PA 200 h PA 1 h PA K PA 20 K PA 0 K PA inch H2O 80 2 inch H2O 0 05 inch H2O Atmosphere 0 2 Atmosphere 0 001 Atmosphere Unit Max range Accuracy mbar 200 mbar 2 F S psi 2 9 psi Kg cm 2 0 2 Kg cm 2 Note mm Hg 150 mm Hg 23 5 inch Hg 5 91 inch Hg F S full scale meter H2O 2 040 meter H2O Included linearity h PA 200 h PA hysteresis and K PA 20 K PA repeatability inch H2O 80 2 inch H2O Atmosphere 0 2 A...

Страница 8: ...Remark Measuring Display unit unit psi PSI inch Hg In Hg inch H2O In H2O h PA h PA KPA _ PA mbar bAr Kg cm 2 _ g C2 mm Hg Hg meter H2O t H2O Atmosphere AtP 6 ...

Страница 9: ...dapter Input Socket 3 4 REC Button 3 15 Battery Compartment Cover 3 5 UNIT Button Button 3 16 Battery Cover Screws 3 6 Function Button Button 3 17 Stand 3 7 Set Button Time Button 3 18 Tripod Fix Nut 3 8 Log Button Enter Button 3 19 Plug quick coupler 3 9 P1 Input Socket 3 20 Pitot Tube 3 10 P2 Input Socket 3 21 soft tube 3 11 SD card socket 3 22 soft tube 7 ...

Страница 10: ... 3 5 Fig 1 to Select the desired Air vilocity units m s Ft min Km h Knot Mile h 4 Zero adjusting pressing and holding the the Button 3 5 Fig 1 and Button 3 6 Fig 1 for at least 1 5 seconds to the display reading will show zero 5 Pitot tube sensing soft tube 3 22 Fig 1 Install to P1 Input Socket 3 9 Fig 1 and sensing soft tube 3 21 Fig 1 Install to P2 Input Socket 3 10 Fig 1 6 The meter is build th...

Страница 11: ...djusting pressing and holding the the Button 3 5 Fig 1 and Button 3 6 Fig 1 for at least 1 5 seconds to the display reading will show zero 5 Install the measuring pipe to Plug quick coupler 3 19 Fig 1 6 The meter is build the two input socket P1 input socket P2 input socket for accepting the differential pressure input Connecting the pipe along the Plug 3 19 Fig 1 to a P1 input socket 3 9 Fig 1 on...

Страница 12: ...tton 3 4 Fig 1 once to start the Data Record function and there will be a REC symbol on the display 2 With the REC symbol on the display a Press the REC Button 3 4 Fig 1 once the REC MAX symbol along with the maximum value will appear on the display b Press the REC Button 3 4 Fig 1 again the REC MIN symbol along with the minimum value will appear on the display c To exit the memory record function...

Страница 13: ...R ZERO ADJUST ON DETERMINE UNIT Optional measuring procedures DATA HOLD MEMORY RECORD RS232 OUTPUT Max Min datalogger function Auto datalogger function or Manual datalogger function Power management AUTO POWER OFF or MANUAL POWER OFF Not activated during Memory Record Selection 11 ...

Страница 14: ...ng If the meter is used at first time it should to adjust the clock time exactly please refer chapter 7 1 page 18 d Decimal format setting The numerical data structure of SD card is default used the as the decimal for example 20 6 1000 53 But in certain countries Europe is used the as the decimal point for example 20 6 1000 53 Under such situation it should change the Decimal character at first de...

Страница 15: ...n the DATALOGGER symbol will flashing c Finish the Datalogger During execute the Datalogger function press the LOG Button 3 8 Fig 1 1 5 seconds continuously again will finish the Datalogger function the DATALOGGER text will be disappeared and finish the Datalogger function 5 3 Manual Datalogger Set sampling time 0 second a Set sampling time is to 0 second Press the LOG Button 3 8 Fig 1 1 5 second ...

Страница 16: ...Datalogger 5 4 To check the time and sampling time information During the normal measurement not execute the Datalogger If press Time 3 7 Fig 1 once the LCD display will present the time information of Year Month Date Hour Minute Second and the Sampling time information 5 5 SD Card Data structure 1 When the SD card is used into the meter the SD card When the first time the SD card is used into the...

Страница 17: ... the total files more than 99 files will generate anew route such as PMA02 4 The file s route structure PMA01 PMA01001 XLS PMA01002 XLS PMA01099 XLS PMA02 PMA02001 XLS PMA02002 XLS PMA02099 XLS PMAXX Remark XX Max value is 10 15 ...

Страница 18: ...e SD card into the SD card adapter then connect the SD card adapter into the computer 3 Power ON the computer and run the EXCEL software Download the saving data file for example the file name PMA01001 XLS PMA01002 XLS from the SD card to the computer The saving data will present into the EXCEL software screen for example as following EXCEL data screens then user can use those EXCEL data to make t...

Страница 19: ...EXCEL graphic screen for example graphic 17 ...

Страница 20: ...ON OFF DEC Set SD card Decimal character SD F SD memory card Format dnSt Air density Remark During execute the Advanced Setting function if press HOLD Button 3 3 Fig 1 will exit the Advanced Setting function the LCD will return to normal screen 7 1 Set clock time Year Month Date Hour Minute Second When the upper display show dAtE 1 Use the Button 3 5 Fig 1 or Button 3 6 Fig 1 to adjust the value S...

Страница 21: ...e Button 3 5 Fig 1 or Button 3 6 Fig 1 to adjust the value Setting start from Hour value After the desired value is set press the Enter Button 3 8 Fig 1 once will going to next value adjustment for example first setting value is Hour then next to adjust Minute Second value Remark The adjusted value will be flashed 2 After set all the time value Hour Minute Second press the Set Button 3 7 Fig 1 onc...

Страница 22: ...ith default 2 After select the upper text to YES or no press the Enter Button 3 8 Fig 1 will save the setting function with default 7 5 Decimal point of SD card setting The numerical data structure of SD card is default used the as the decimal for example 20 6 1000 53 But in certain countries Europe is used the as the decimal point for example 20 6 1000 53 Under such situation it should change the...

Страница 23: ...in the Display will show text Ent Sd F to confirm again if make sure to do the SD memory card format then press Enter Button once will format the SD memory clear all the existing data that already saving into the SD card 7 7 Air density When the lower display show dnSt At this time first digit of will flash Use the Button 3 5 Fig 1 or Button 3 6 Fig 1 to adjust the value Air density After the desi...

Страница 24: ... instrument become inaccurate 2 Loose the screws of the Battery Cover 3 16 Fig 1 and take away the Battery Cover from the instrument and remove the battery 3 Replace with DC 1 5 V battery UM3 AA Alkaline heavy duty x 6 PCs and reinstate the cover 4 Make sure the battery cover is secured after changing batteries 10 SYSTEM RESET If the meter happen the troubles such as CPU system is hold for example...

Страница 25: ...ig 1 The data output is a 16 digit stream which can be utilized for user s specific application A RS232 lead with the following connection will be required to link the instrument with the PC serial port Meter PC 9W D Connector Center Pin Pin 4 3 5 mm jack plug Ground shield Pin 2 2 2 K resister Pin 5 23 ...

Страница 26: ...splay mbar 86 psi 23 m s 08 mm Hg 78 inch Hg 80 Km h 10 inch H2O 25 Kg cm2 77 ft min 11 Atmosphere 26 meter H2O 79 mile h 12 K PA 88 h PA 91 Knot 09 D10 Polarity 0 Positive 1 Negative D9 Decimal Point DP position from right to the left 0 No DP 1 1 DP 2 2 DP 3 3 DP D8 to D1 Display reading D1 LSD D8 MSD For example If the display reading is 1234 then D8 to D1 is 00001234 D0 End Word RS232 FORMAT 96...

Страница 27: ...U801 WIN is a multi Acquisition displays 1 2 4 6 8 displays software powerful application software SW U801 WIN provides the functions of data logging system text display angular display chart display data recorder high low limit data query text data recorder high low limit data report chart report xxx mdb data file can be retrieved for EXCEL ACESS wide intelligent applications Power adapter AC 110...

Страница 28: ...ter SD card structure already get patent or patent pending in following countries Germany Nr 20 2008 016 337 4 JAPAN 3151214 TAIWAN M 358970 M 359043 CHINA ZL 2008 2 0189918 5 ZL 2008 2 0189917 0 USA Patent pending 26 ...

Отзывы: