background image

Function menu 

In the main interface, press the "menu" key to enter the setup menu, each time press 

the "menu" button to switch to the next item: 

(1) System time setting: Press "Select" key to adjust the cursor position, press "

" "

" to adjust the system time, after adjustment, press "menu" or "return" key to take effect;

(2) System date setting: Press "Select" key to adjust the cursor position, press "

" "

" to adjust the system date, after adjustment, press "menu" or "return" key to take effect;

(3) System language selection: Press "

" "

" to select the language, press "menu" or

"return" key to take effect; 

(4) To delete the sampled data: Press  "

"  "

  to select  whether to  delete the saved

sample  data.  If  you  want  to  delete,  select"  Yes  "and  press  the"  Start  "button  to  indicate 

whether to delete and select" Yes " Press the "Start" button to take effect. Note: Deleting 

data will clear all sampling records. Please choose carefully. 

View the record 

In the main interface, press the "Select" button to enter the record query interface, you 

can  view  all  the  sampling  record  data  (including  sampling  date,  sampling  gas  group 

number,  sampling  volume  and  other  information),  recorded  in  ascending  order,  save  the 

new record On the last page, press the "Select" button to adjust the cursor position, press "

" "

" to page, press "Back" to return to the main interface.

IX. Maintenance and Precautions

1. Do not use in a strong acid and alkali environment, not in the dust concentration greater

than 0.3mg / m3 in the use of the environment. 

2. After use, to clean the sampling head and gas dispersing head with alcohol, and cover

the gas dispersion head to the sampling head. 

3. In the clean stainless steel shell, you can first use mild soapy water to clean, and then

gently  wipe  with  a  soft  cloth  (if  bacterial  contamination,  with  70%  isopropyl  alcohol 

solution). Please do not use acid, alkali and chlorine solution and salt solution to clean the 

Содержание AIS-4

Страница 1: ...Compressed Air Sampler Instruction ISO9001 2008 Certified Enterprise PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 mrc mrclab com MRC...

Страница 2: ...oper use of this equipment please keep it for future reference Directory I Equipment Introduction 1 II Application 1 III Working Environment 1 IV Main Features 1 V Technical Parameters 2 VI Product Li...

Страница 3: ...etsec 23 1 to 23 5 m sec at 200 L min The surface of the medium is equivalent an 1hAnderson Principle 5 Grade 6 at 200L min ensuring that all particles larger t ish wasdmicron 0 65 micron at 200L min...

Страница 4: ...pling design the sampling head with up to 300 microporous so that micro organisms evenly distributed in the surface of the medium to reduce the dust bacteria overlap effectively reduce the microbial c...

Страница 5: ...set Lithium battery charger DC 8 4V 1000mA 1set Manual certificate warranty card 1 set USB data cable 1 Piece VII Structural Features 1 The composition of the sampler includes gas dispersing head sam...

Страница 6: ...4 quick connector gas dispersing head sampling head air pressure regulating valve control panel gas flow meter outlet air inlet switch charging interface purifier internal...

Страница 7: ...ired for microbial culture according to the requirements of the experiment and prepare the corresponding plate Before starting sampling make sure that the storage temperature of the sampling petri dis...

Страница 8: ...state please open the external compressed gas tank valve compressed gas will be through the air inlet pressure control valve gas flow See section 4 of this chapter After adjustment press Start to proc...

Страница 9: ...or 30 minutes or wiped with 75 alcohol at the high pressure steam sterilizer The gas dispersing head the Petri dish and the appearance of the instrument are also used 75 alcohol for wipe sterilization...

Страница 10: ...lly lock the baffle screws 5 the system function menu description Working mode selection In the main interface press key to select the working mode as program control manual control self purification...

Страница 11: ...all sampling records Please choose carefully View the record In the main interface press the Select button to enter the record query interface you can view all the sampling record data including sampl...

Страница 12: ...thod not mentioned above consult the manufacturer or agent to determine if the method used will damage the instrument 6 The display shows that when the battery power is low the battery is displayed as...

Отзывы: