background image

mr

.

steam

®

         

Steam@Home

®

 

Installation, Operation & Maintenance Manual

________________________________________________________________________

IN

S

T

A

L

L

E

R

 

LIQUID LEVEL CoNtroL BoArD

 

Explanation of LED Indicators

_________________________________________________________________________________________________
GREEN  

LED is ON when there is 208/240 Volt incoming power connected, 24 Volt  

 

transformer secondary output and on-board 5 Volt DC control power are present.

_________________________________________________________________________________________________
YELLOW  

Water level indicator–LED is OFF when no water is detected (for more that 5 seconds). 

 

ON when water level is satisfactory. 

_________________________________________________________________________________________________
RED 

Contactor relay indicator–LED is ON when relay is closed and sending 24 Volts to the  

 

contactor coil.  (This LED comes ON if the generator is ON.)

__________________________________________________________________________________________________
 

Liquid Level Control Board 

PN 103975B

(shown without wiring)

10

RED 

(Heater)

YELLOW 

(Water Level)

GREEN 

(Power)

FACTORY
WIRING

FIELD
WIRING

L E G E N D

(All Diagrams)

SteamStart™

SINGLE PHASE 208/240 VoLt WIrING DIAGrAMS 

SAH units are not available in 3 phase

MODELS:

SAH3000
SAH4500  
SAH6000

Содержание Steam@Home 3000

Страница 1: ...Steam Home RESIDENTIAL STEAM GENERATOR SYSTEMS Models SAH3000 SAH4500 SAH6000 Installation Operation Maintenance Manual mr steam Feel Good Inc...

Страница 2: ...ternal human body temperature and impair the body s ability to regulate its inter nal temperature hyperthermia Limit your use of steam to 10 15 minutes until you are certain of your body s reaction WA...

Страница 3: ...Steam Outlet Safety Valve Drip Pan 6 Steam Head Installation 7 Electrical Specifications Field Power Wiring 8 Initial Start Up Checkout 9 Troubleshooting System Status Code 9 Wiring Diagrams Liquid L...

Страница 4: ...r glass tile and or for rooms hav ing a ceiling height in excess of 8 feet IMPORTANT NOTE The total room volume allows for a maximum of 60 feet of insulated steam line from the SAH generator to the st...

Страница 5: ...face such as tile molded acrylic or fiberglass The ceiling should be sloped to prevent drip ping of condensate If acrylic or fiberglass are used as part of the steam room enclosure Consult with the ma...

Страница 6: ...ion and disconnection of piping 11 The SteamStart control may be located inside the steam room or outside of the steam room See SteamStart Installation section pg 12 for specific details NOTE MrSteam...

Страница 7: ...fiberglass and other non heat resistant enclosures for recommended steamhead location Use Acrylic Shield PN MS 103938 See instructions provided with steam shield NOTE For illustrative purposes only C...

Страница 8: ...from unit to steam head as permitted by codes 3 Insulate steam line using pipe insulation rated 250 F minimum 4 Pitch steam line 1 4 per foot towards steam head or steam generator to avoid valleys and...

Страница 9: ...compound is used IMPORTANT NOTE to preserve steam head finish do not use wrench or other tools to tighten DO NOT use abrasive cleansers or chemicals Use only water with mild soap and a non abrasive sp...

Страница 10: ...5 Use two wire supply source and equipment 8 Contactor Power Supply Opening Control Connection See page 12 for Wiring Field Wiring Ground Conductor Terminal FIELD POWER WIRING Models SAH3000 SAH4500...

Страница 11: ...SteamStart button Replace LLCB if code remains TROUBLESHOOTING ELECTRICAL SHOCK HAZARD MrSteam steam generators are connected to 240V line voltage and contain live electrical com ponents All installa...

Страница 12: ...level indicator LED is OFF when no water is detected for more that 5 seconds ON when water level is satisfactory ______________________________________________________________________________________...

Страница 13: ...n in closed position Stainless Steel Tank Heating Element Contactor Power Supply Opening Steam Outlet ___________________________________________ Part Description _____________________________________...

Страница 14: ...ator Be careful not to strain pinch or otherwise damage the control cable StEP 3 Diagram 4 Remove and discard the peel off paper from the switch housing to expose the adhesive as shown in Diagram 4 St...

Страница 15: ...m AromaSteam steamhead recess prior to turning on the steambath Do not place drops in a hot steam head as SERIOUS INJURY CAN RESULT IF YOU DO NOT FOLLOW THIS WARNING Start with one drop to gauge stren...

Страница 16: ...____________________________________________________________________________________________________________________________________ 2017 Sussman Automatic Corporation I MrSteam and des A Lifetime of...

Отзывы: