mr. steam Steam@Home 3000 Скачать руководство пользователя страница 9

mr

.

steam

®

         

Steam@Home

®

 

Installation, Operation & Maintenance Manual

________________________________________________________________________

IN

S

T

A

L

L

E

R

 

7

STEP 2

STEP 3

STEP 4

Steam Supply P ipe

Use Teflon or equal seal-

ant on pipe threads

End of pipe to be 
recessed 

1/8” 

(

with Acrylic Shield

)

Apply with silicone or 

equal sealant as required 

for moisture seal.

Acrylic Shield

(

PN

 

103938)

Steamhead

with Acrylic Shield

Locating Nipple

Apply silicone 

  in groove.

Oil Well

Oil Well

Acrylic Shield

(

PN

 

103938)

INSTALLATION OF THE STEAM HEAD 

(

1

2

 

NPT, PN 103937) 

WITH ACRYLIC SHIELD

 

(PN 103938)

 

The Acrylic Shield (PN 103938) is for use when acrylic or other  
non-heat resistant materials are used for the steamroom enclosure.

                        INSTALLER: Because the steam head and  
direct steam emissions are very hot, locate the steam head where inci-
dental contact by bather with the steam head or direct steam emission 
cannot occur.

IMPORTANT NOTE

These instructions are only for use in  

installations using an Acrylic Shield (pur 103938).

Step 1  
  Locate steam head at least 12 inches from an adjacent wall or bench 

and 6-12 inches above floor, except for tub/shower  
enclosures, install 6 inches above tub top edge. 

  The steamhead shall be installed with the oil well facing up as shown. 

Hand tightening is sufficient when teflon or equal pipe thread sealing 
compound is used.

IMPORTANT NOTE

to preserve steam head finish, do not use 

wrench or other tools to tighten. DO NOT use abrasive cleansers or 
chemicals. Use only water with mild soap and a non-abrasive sponge. 

 

           Consult with supplier of acrylic, fiberglass and other 

non-heat resistant enclosures for recommended steamhead location. 

Step 2  

Secure a bronze drop ear fitting to a header and run a 

1

2

” copper 

steam line from the steam generator to the drop ear fitting. Install 
a temporary nipple (6” or longer)in the drop ear fitting to locate the 
steamhead after the wall is finished. 

Step 3  

After the wall has been finished, mark on the nipple where the surface 
of the wall is. Remove the nipple and measure the portion that was in 
the wall (the end to your mark).  Subtract 1⁄8” from that dimension 
and select a brass nipple of that length to finish the installation.

Step 4 

Wrap teflon tape around the threads of the new nipple and screw the 
nipple into the steamhead. Do not use wrenches or tools which would 
damage the steamhead’s finish. 

  Slide the acrylic shield onto the nipple-steamhead assembly  

so the steam head sits in the acrylic shield.

  Apply clear silicone in the groove on the back of the acrylic shield.
  Wrap teflon tape around the threads of the nipple and screw the nipple 

and steamhead assembly you just made into the drop ear fitting in the 
wall.  The steamhead should be flush with the wall and the well must 
be facing up. The acrylic shield will be sandwiched between the wall 
and steam head.

!

C A U T I O N

!

C A U T I O N

Содержание Steam@Home 3000

Страница 1: ...Steam Home RESIDENTIAL STEAM GENERATOR SYSTEMS Models SAH3000 SAH4500 SAH6000 Installation Operation Maintenance Manual mr steam Feel Good Inc...

Страница 2: ...ternal human body temperature and impair the body s ability to regulate its inter nal temperature hyperthermia Limit your use of steam to 10 15 minutes until you are certain of your body s reaction WA...

Страница 3: ...Steam Outlet Safety Valve Drip Pan 6 Steam Head Installation 7 Electrical Specifications Field Power Wiring 8 Initial Start Up Checkout 9 Troubleshooting System Status Code 9 Wiring Diagrams Liquid L...

Страница 4: ...r glass tile and or for rooms hav ing a ceiling height in excess of 8 feet IMPORTANT NOTE The total room volume allows for a maximum of 60 feet of insulated steam line from the SAH generator to the st...

Страница 5: ...face such as tile molded acrylic or fiberglass The ceiling should be sloped to prevent drip ping of condensate If acrylic or fiberglass are used as part of the steam room enclosure Consult with the ma...

Страница 6: ...ion and disconnection of piping 11 The SteamStart control may be located inside the steam room or outside of the steam room See SteamStart Installation section pg 12 for specific details NOTE MrSteam...

Страница 7: ...fiberglass and other non heat resistant enclosures for recommended steamhead location Use Acrylic Shield PN MS 103938 See instructions provided with steam shield NOTE For illustrative purposes only C...

Страница 8: ...from unit to steam head as permitted by codes 3 Insulate steam line using pipe insulation rated 250 F minimum 4 Pitch steam line 1 4 per foot towards steam head or steam generator to avoid valleys and...

Страница 9: ...compound is used IMPORTANT NOTE to preserve steam head finish do not use wrench or other tools to tighten DO NOT use abrasive cleansers or chemicals Use only water with mild soap and a non abrasive sp...

Страница 10: ...5 Use two wire supply source and equipment 8 Contactor Power Supply Opening Control Connection See page 12 for Wiring Field Wiring Ground Conductor Terminal FIELD POWER WIRING Models SAH3000 SAH4500...

Страница 11: ...SteamStart button Replace LLCB if code remains TROUBLESHOOTING ELECTRICAL SHOCK HAZARD MrSteam steam generators are connected to 240V line voltage and contain live electrical com ponents All installa...

Страница 12: ...level indicator LED is OFF when no water is detected for more that 5 seconds ON when water level is satisfactory ______________________________________________________________________________________...

Страница 13: ...n in closed position Stainless Steel Tank Heating Element Contactor Power Supply Opening Steam Outlet ___________________________________________ Part Description _____________________________________...

Страница 14: ...ator Be careful not to strain pinch or otherwise damage the control cable StEP 3 Diagram 4 Remove and discard the peel off paper from the switch housing to expose the adhesive as shown in Diagram 4 St...

Страница 15: ...m AromaSteam steamhead recess prior to turning on the steambath Do not place drops in a hot steam head as SERIOUS INJURY CAN RESULT IF YOU DO NOT FOLLOW THIS WARNING Start with one drop to gauge stren...

Страница 16: ...____________________________________________________________________________________________________________________________________ 2017 Sussman Automatic Corporation I MrSteam and des A Lifetime of...