![mr. steam Feel Good AromaSteam Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/mr-steam/feel-good-aromasteam/feel-good-aromasteam_installation-operation-and-maintenance-manual_1845357008.webp)
Installing the 90 degree T and Check Valve
1. For optimal results locate a brass 90 degree
T
(not provid-
ed) in the steam supply line within 5-10 feet of the steam
head. If using copper tubing for steam lines, install a female
1/2 NPT or 1/4 NPT reducing Tee in the steam line facing
downward.
2.
T
must face downward as shown.
IMPORTANT NOTE:
Follow the installation instructions for
the steam pipeline in the MrSteam Steam Bath Installation and
Operation Manual. Visit www.mrsteam.com to download this
document.
3. Install Check Valve into 90˚
T
/adaptor.
The Check Valve prevents excessive amounts of
fragrance from entering the steam line and steam room. Never
install the AromaSteam System without the Check Valve.
Failure to install the Check Valve may result in excessive fra-
grance delivery into the steam room and cause dizziness and/
or personal injury.
PRESSURE TUBE ASSEMBLY
For your convenience the pressure tube assembly is provided pre-
assembled. If additional tubing is needed please contact MrSteam
Technical service at 1-800-767-8326 or 1-800-727-8326.
Installation of Pressure Tube to the Pump
1. Insert the pressure tube through the hole of the pump tight-
ening nut and collar and firmly push the tube onto the tube
holder.
2. Screw the pump tightening nut onto the pump and tighten the
nut by HAND only.
Installation of Pressure Tube to the 90˚ T
1. Insert the pressure tube through the Check Valve tightening
nut and collar and firmly push the pressure tube onto the tube
holder.
2. Screw the Check Valve tightening nut onto the Check Valve.
IMPORTANT NOTE:
To prevent connection from leaking, insert
tubing holder completely into tubing until it reaches the bottom.
Lubricate the ID of the tubing as required with soap to facilitate
insertion.
IMPORTANT NOTE:
To prevent damage do not use tools to
tighten the nut.
WARNING
!
Steam Pipe
(not supplied)
Adapter
(not supplied)
Check Valve
Tube Holder
Collar
Check Valve
Tightening Nut
Pressure Tube
Pump
Tightening
Nut
Collar
Tube Holder
Pump
90˚ Tee
(not supplied)
I N S T A L L E R S E C T I O N
AromaSteam
Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
8