![mr. steam Feel Good AromaSteam Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/mr-steam/feel-good-aromasteam/feel-good-aromasteam_installation-operation-and-maintenance-manual_1845357006.webp)
I N S T A L L E R S E C T I O N
AromaSteam
Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
6
5 -10 ft. optimal
(
6 ft.
)
2 ft. max
Steam
Pipe
Steam
Generator
Steam
Pipe
T
Check Valve
Suction
Hose
Pump Line Cord 120V
(to grounded outlet)
Fragrance
Caddy
Request Cable
(
to Steam Generator
)
Steam Head
(inside steam room)
Pressure Hose
Pump
General System Dimensions
PUMP SPECS
Dimensions: 7.5”W x 4.5”H x 4.5”D
Weight: 5 pounds
Motor voltage 120VAC, 50/60 Hz
Current Draw 0.5 Amps
(
6 ft.
)
(11.5
ft.
)