Electrical Connection of AromaSteam
System
This AromaSteam system is factory
wired. If the power cord of the AromaSteam pump
is damaged it must be replaced by the MrSteam
service department or similarly qualified personnel
in order to avoid an electric shock hazard. All elec-
trical connections to be made by a licensed, quali-
fied electrician. Disconnect all power to the steam
generator before making power connections.
IMPORTANT NOTE:
AromaSteam system is for
use with AirTempo
®
iSteam
®
and iTempoPlus
®
con-
trols only.
1. Disconnect all power to the MrSteam steam
generator. Failure to disconnect power may
result in an electrocution hazard. Remove the
top cover.
2. Run the request cable from the AromaSteam
pump through one of the knock outs in the side
vÊÌ iÊÃÌi>ÊL>Ì Ê}iiÀ>ÌÀ°Ê1ÃiÊ>ÊÃÌÀ>ÊÀiiv
bushing or grommet to prevent chafing.
3. Locate the two quick connect tabs labeled
“AROMA” on the printed circuit board in the
location shown.
4. Connect the request cable to the terminals.
The terminals are not polarized.
AromaSteam Wiring Schematic
AromaSteam Connections
Steam Generator
Circuit Board
CAUTION
!
Plug
120 VAC
Outlet
(grounded receptacle
required)
Request Cable
24 VAC
to steam generator
AromaSteam Pump
Steam
Line
Knock Out
Steam Generator
Printed Circuit Board
Typical MrSteam
Steam Generator
(
shown with
cover removed
)
Request Cable
Pump
I N S T A L L E R S E C T I O N
AromaSteam
Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
11