Installation, Operating & Maintenance Manual
5
DIMENSIONS & CLEARANCE SPECIFICATIONS
Figure 2:
Typical Arrangement of Boiler with McDonnell Miller.
For illustration purposes only. Refer to all notes below
NOTES FOR FIGURE 2:
1.
All dimensions are approximate. Refer to chart on Page 5.
2
. MM150 Liquid Level Control on CU-2000 and larger models only.
CU-360 to CU-1400 have electronic liquid level controls.
3. IMPORTANT
:
Minimum clearance from combustible surfaces.
Refer to Fig. 2 above for legend.
A
1" above top of CU generator
B
Front of CU generator suitable for alcove installation only.
D
1" from rear of CU generator.
EL
1" from left side of CU generator.
ER
16" from right side of CU generator.
F
Type of flooring: “C", suitable for combustible flooring.
4.
For ease of servicing, Mr. Steam recommends a minimum of
36 inches of clearance all around the CU generator.