CONTROL CIRCUIT WIRING DIAGRAM
SEE PAGES 11, 12 & 13 FOR DIAGRAMS
Installer shall use a safety switch of adequate capacity employing
suitably rated circuit breakers or fuses between main electrical
power source(s) and the generator. Location of safety switch to be in
accordance with National and local electrical codes.
NOTES:
1. Larger rooms may require two or more steam solenoid valves in parallel.
2. When generator services two rooms, second room requires a set of
Digital 1
®
and solenoid valves.
IMPORTANT:
3. Digital 1
®
sensors are intended to be field installed within the steam
room at the location selected by the designer/architect. DO NOT
LOCATE THE Digital 1 SENSOR NEAR OR ABOVE THE STEAMHEAD(S)
AS THIS MAY CAUSE DIRECT STEAM EMISSION TO INTERFERE WITH
STEAMROOM TEMPERATURE REGULATION.
4. Autoflush System 24 hr. timer and Digital 1
®
operating settings are at
the discretion of the owner/operator.
IMPORTANT:
Owners/operators should obtain a copy and familiarize
themselves with the latest edition of the American College of Sports
Medicine Health/Fitness Faculty Standards and Guidelines, or a similar
resource and reference publication, and refer to those guide lines for the
proper and safe operation of a spa facility including steam rooms. Steam
room construction information is avail-able from the Tile Council of
America, Inc. at (864) 646-8453 or www.tileusa.com.
The Digital 1
®
Temperature Control System is required
operating equipment for each steam room. The operating temperature
control is to be set by the owner/operator to sense desired room tempera-
ture at the sensor location within the steam room. Connection of the Over
Temperature portion of the Digital 1 control is mandatory to provide addi-
tional protection to the bathers. The steam room is to be operated in
accordance with “Important” information as noted above.
IMPORTANT:
Final selection of the steam room temperature setting is at the discretion
of the owner/operator.
Ensure all splices in the sensor cable are securely
crimped soldered and sealed with heat shrink tubing.
WARNING
!
WARNING
!
CAUTION
!