mr
.
steam
Operating Instructions
________________________________________________________________________________________________
11
mr
.
steam
Installation Instructions
________________________________________________________________________________________________
10
Silicone Sealant
Cable
Wall
1⁄4" minimum
1⁄2" maximum
5.
Route the end of the probe cable with the temperature probe
through the wall into the steam room as shown in Diagram 2.
impOrtaNt NOte:
Do not strain, staple, pinch or otherwise
damage the probe cable.
6.
With a minimal length of the cable exposed apply silicone
(provided) to the hole in the wall as required to create a mois-
ture seal as shown in Diagram 2.
7.
Push the temperature cable and probe into hole as required to
leave minimum 1/4”, maximum 1/2” of the bulb exposed as shown
in Diagram 3.
WarNiNG
!
WarNiNG
!
Sectional View
steam
room
interior
Diagram 2 Diagram 3
Insure a minimum of 1/4” of the temperature probe is exposed
to the air. Failure to do so may interfere with the ability to sense tempera-
ture and may result in excessive steam room temperatures.
The exposed area of the temperature probe must be free of
silicone or any materials or obstructions that prevent direct exposure to the
steam room air. Failure to do so may interfere with the ability to sense tem-
perature and
may result in excessive steam room temperatures.
NOte:
For Illustrative Purposes Only. Drawings Not to Scale
The AirTempo features programmable temperature
control, programmable time duration, AromaSteam
ON/OFF, ChromaSteam
®
control and two personal
settings.
The LCD will be OFF until a button is pressed. The
LCD remains lit for 10 seconds after the last button
is pressed. When the steam generator turns OFF
the display will turn on and read OFF. While the
generator is steaming the LED above AROMA and
CHROMA will alternately flash every 2 seconds.
Set the steam bathing temperature
according to personal preference, however it is
highly recommended to begin steam bathing at a
low temperature setting for a very short duration to
gauge comfort and safety levels.
airtempo
Operating instructions
Diagram 1
Diagram 2
ON/OFF
Time
WarNiNG
!
ON/OFF
Diagram 1
Press the ON/OFF key for 1 second to start the
flow of steam. The Temperature Set Point is
displayed. Steam will begin to flow a few minutes
after the control is turned ON. The duration re-
quired for the steam room to reach steam bathing
temperatures depends on the steam room
construction and steam generator specifications.
To stop the flow of steam before time expires press
the ON/OFF key. Steam may continue to flow
for a short time after the control is turned OFF
SettiNG tHe SteamBatH DUratiON
Diagram 2
Press TIME key to set or display the steambath
duration time. The control is pre-set and will display
a TIME setting of 20 minutes (default setting).
With the TIME displayed, press the LEFT or RIGHT
arrows to set the desired duration time (2-60
minutes) in two minute increments.
installed remote temperature probe
showing a minimum of 1/4” of the probe
exposed to steam room air