mr. steam AirTempo Скачать руководство пользователя страница 6

mr

.

steam

  

Operating Instructions

________________________________________________________________________________________________

11

mr

.

steam

  

Installation Instructions

________________________________________________________________________________________________

10

Silicone Sealant

Cable

Wall

1⁄4" minimum

1⁄2" maximum

5. 

Route the end of the probe cable with the temperature probe 

through the wall into the steam room as shown in Diagram 2.

impOrtaNt NOte: 

Do not strain, staple, pinch or otherwise 

damage the probe cable.

6.

 With a minimal length of the cable exposed apply silicone  
(provided) to the hole in the wall as required to create a mois-
ture seal as shown in Diagram 2.

7.

 Push the temperature cable and probe into hole as required to  

leave minimum 1/4”, maximum 1/2” of the bulb exposed as shown 
in Diagram 3.  

WarNiNG

!

WarNiNG

!

Sectional View

steam

 

room

 

interior

Diagram 2                                                 Diagram 3

 

Insure a minimum of 1/4” of the temperature probe is exposed 

to the air. Failure to do so may interfere with the ability to sense tempera-
ture and may result in excessive steam room temperatures.

 

The exposed area of the temperature probe must be free of 

silicone or any materials or obstructions that prevent direct exposure to the 
steam room air. Failure to do so may interfere with the ability to sense tem-
perature and 

may result in excessive steam room temperatures.

NOte:

 For Illustrative Purposes Only. Drawings Not to Scale

The AirTempo features programmable temperature 
control, programmable time duration, AromaSteam 
ON/OFF, ChromaSteam

®

 control and two personal 

settings.

The LCD will be OFF until a button is pressed.  The 
LCD remains lit for 10 seconds after the last button 
is pressed. When the steam generator turns OFF 
the display will turn on and read OFF. While the 
generator is steaming the LED above AROMA and 

CHROMA will alternately flash every 2 seconds.

 

Set the steam bathing temperature 

according to personal preference, however it is 
highly recommended to begin steam bathing at a 
low temperature setting for a very short duration to 
gauge comfort and safety levels.

airtempo

 

Operating instructions

Diagram 1

Diagram 2

ON/OFF

Time

WarNiNG

!

ON/OFF  

Diagram 1

Press the ON/OFF key for 1 second to start the 

flow of steam. The Temperature Set Point is 

 

displayed. Steam will begin to flow a few minutes 

after the control is turned ON. The duration re-
quired for the steam room to reach steam bathing 
temperatures depends on the steam room  
construction and steam generator specifications. 

To stop the flow of steam before time expires press 
the ON/OFF key.  Steam may continue to flow 

 

for a short time after the control is turned OFF

SettiNG tHe SteamBatH DUratiON  

Diagram 2

 

Press TIME key to set or display the steambath  
duration time. The control is pre-set and will display 
a TIME setting of 20 minutes (default setting).  
With the TIME displayed, press the LEFT or RIGHT 
arrows to set the desired duration time  (2-60  
minutes) in two minute increments.

installed remote temperature probe

showing a minimum of 1/4” of the probe 

exposed to steam room air 

Содержание AirTempo

Страница 1: ...Operating Maintenance Instructions ________________________________________________________________________________________________ 1 AirTempo Wireless Touch Control with Steamhead Installation Operat...

Страница 2: ...ing and caution symbols This blocked information is important for the safe and ef ficient installation and operation of the steambath system These are types of potential hazards that may occur during...

Страница 3: ...quate heating of the steam room If an AirTempo iSteam iTempo or iTempoPlus control is installed outside the steam CAUTION room a Remote Temperature Probe PN MSTS must be installed inside the steam roo...

Страница 4: ...he surface mount bayonet supports the weight of the AitTempo control if requires use the screw and anchor provided to secure the bayonet to the wall When installing AirTempo on glass the peel and stic...

Страница 5: ...ar the steamhead or near direct steam emis sions may result in poor steam room temperature control d The probe has an integral 30 cable Insure that the probe and or steam generator are located accordi...

Страница 6: ...irTempo features programmable temperature control programmable time duration AromaSteam ON OFF ChromaSteam control and two personal settings The LCD will be OFF until a button is pressed The LCD remai...

Страница 7: ...steambath will operate at the stored settings Diagram 3 Diagram 4 TEMP Time Temperature adjustment User Preset AromaSteam The AromaSteam is an optional accessory that automatically injects aromatic oi...

Страница 8: ...splay a status code if the steam system is not function ing correctly Err C indicates the AirTempo control has lost communication with the steam generator Ensure all connections are secure between the...

Страница 9: ...pourraient annuler l autorit de l utilisateur utiliser cet quipement Parts List Item Description Used on 104208BK Electronic Assembly Black All 104208WH Electronic Assembly White All 104209 Retention...

Страница 10: ...18 19...

Страница 11: ...n call Sales Support at 1 800 76 STEAM East Coast 1 800 72 STEAM West Coast mr steam Sussman Automatic Corporation hello mrsteam com www mrsteam com 43 20 34th Street Long island City NY 11101 9410 S...

Отзывы: