background image

7

Operating Instructions and Owner’s Manual

Mr. Heater | Gas-Fired Infra-Red Portable Heater

7. SHUTDOWN AND STORAGE

INSTRUCTIONS

A.

The bulk propane tank “on-off” valve should ALWAYS be
completely turned “OFF” when the heater is not in use.

B.

When shutting off the heater, turn the regulator knob on the

heater to “OFF” (clockwise). (See Figure 4)

C.

CAUTION:

 After turning unit off, heater will remain

extremely hot. Allow at least 15 minutes for cooling before
handling and storing. Detach heater from bulk tank before
handling and storage. REMEMBER – POL fitting is a left-hand
thread.

TROUBLE SHOOTING

MR. HEATER APPLIANCE

The chart assumes that the proper gas and gas pressure is available to the heater. The chart also assumes that the heater is used in
accordance with Mr. Heater installation and operating instructions.

If satisfactory results cannot be obtained after performing any of the above procedures,

Please call Mr. Heater’s Customer Care Center at 1-800-251-0001. Thank you.

D.

HEATER STORAGE:

 Always remove the propane cylinder from

the heater when not in use. Always store propane cylinders in
a cool, well ventilated place away from any flame or heat and
in a location not used for habitation. DO NOT STORE PROPANE
TANK WITHIN 60 FT. OF OPEN FLAME OR HEAT.

E.

See Figure 6 for spare parts list.

PROBLEM

POSSIBLE CAUSE

SOLUTION

Burners will not light

Propane tank turned off

Open tank valve

Propane tank empty

Get tank filled

Heater regulator not turned on

Turn valve to medium position

Safety Shutoff plunger not depressed

Depress S/S valve while lighting

Air in manifold or hose or propane tank

Purge air from unit

Hear gas but burners will

Air in propane tank

Return tank to dealer to purge air

not light (hissing)

Defective regulator

Replace

Partially plugged orifice

Clean or replace

Burner lights, turns red but

Thermocouple not secure

Secure thermocouple

will not stay lit

Thermocouple out of position

Position tip 3/16” to 3/8” from screen

Defective thermocouple

Replace thermocouple

Safety shutoff defective

Replace safety shutoff

Blue flame at top of

Out of storage

Clean all openings with H.P. air

heater screen

Defective regulator

Replace regulator

Blue flame only – never gets red

Something in Venturi

Clean venturi tube with wire

Orifice partially plugged

H.P. air clean out venturi/orifices

Screen plugged up

Connection at propane tank

“O-Ring” on POL missing or defective

Replace “O” ring or POL

leaking gas after securing

Valve seat on cylinder worn

Return to dealer

Heater emits high pitched sound

Heater warming up

No Danger – heater warming up.

Sound will stop in 1-3 minutes

Содержание MH42T

Страница 1: ...rty damage personal injury or loss of life WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appli ance WHAT TO DO IF YOU SMELL GAS Do not try to light appliance Extinguish any open flame Shut off gas to appliance Service must be perf...

Страница 2: ...E OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNER DUST PAR TICLES OR UNKNOWN CHEMICALS WARNING COMBUSTION BY PRODUCTS PRODUCED WHEN USING THIS PRODUCT CONTAIN CARBON MONOXIDE A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM WARNING NOT FOR HOME OR RECREATIONAL VEHICLE USE WARNING YOUR SAFETY IS IMPORTANT TO YOU AN...

Страница 3: ... 1 5 Make sure tank valve is in OFF position clockwise 1 6 Make sure regulator knob is in OFF position by turning knob clockwise to off 1 7 Carefully screw POL nut directly into bulk tank valve finger tight turning counterclockwise then with a 7 8 open end wrench tighten the POL fitting hard 1 8 Always connect the heater to bulk tank in the outdoors or in a well ventilated area NEVER connect heate...

Страница 4: ...cylinder in the outdoors or in a well ventilated area Use a 7 8 open end wrench NEVER connect this heater to a cylinder near an open flame F USE OF HEATER Always operate the heater with the propane cylinder in an upright position on a level noncombustible surface NEVER place the cylinder on its side when operating the heater G ATTEND HEATER Do not leave heater unattended while it is in operation H...

Страница 5: ...lly screw POL nut directly into bulk propane cylinder counterclockwise REMEMBER This is a left hand thread see Figure 1 Make sure the heater is in a vertical upright position and directed away from the collar of the bulk tank Use a 7 8 open end wrench to tighten the POL fitting left hand thread see Fig 1 6 LIGHTING INSTRUCTIONS A Before attempting to light the heater check all fittings and connect...

Страница 6: ...ment Regulator with Soft Nose POL 7 73743 Reflector 8 73742 Wire Guard 9 75607 Metal Ring 10 73938 Collar Mounting Bracket Assembly 11 73658 Hose Assembly Less Regulator 11 Long 12 73213 Replacement Safety Shutoff with Orifice 13 75613 Locking Knob 14 73214 Bolt 20 with Seal Washer 15 73322 Plenum Assembly with Clip Center Only Mr Heater Gas Fired Infra Red Portable Heater Model MH42T Figure 6 Fig...

Страница 7: ...O NOT STORE PROPANE TANK WITHIN 60 FT OF OPEN FLAME OR HEAT E See Figure 6 for spare parts list PROBLEM POSSIBLE CAUSE SOLUTION Burners will not light Propane tank turned off Open tank valve Propane tank empty Get tank filled Heater regulator not turned on Turn valve to medium position Safety Shutoff plunger not depressed Depress S S valve while lighting Air in manifold or hose or propane tank Pur...

Страница 8: ... details concerning the claim Also supply us with the purchase date and the name and address of the dealer from whom you purchased our product The foregoing is the full extent of the responsibility of the Company There are no other warranties express or implied Specifically there is no warranty of fitness for a particular purpose and there is no warranty of merchantability In no event shall the Co...

Отзывы: