background image

4

Mr. Heater | Gas-Fired Infra-Red Portable Heater

Operating Instructions and Owner’s Manual

ODOR FADE WARNING

1.  GENERAL INFORMATION

A.

The Mr. Heater MH42T heaters are high pressure propane

appliances and are designed to be connected to a bulk
propane tank. Every unit is tested during manufacturing and
shipped fully

B.

These heaters are equipped with three automatic Safety

Shutoff Valves. The gas flow will automatically stop the heater
burner if that heater burner fails to operate for any reason.

C.

Maximum safety and convenience have been built into the Hi-

Med-Lo-Off Control Valve/Regulator. The following table lists
the approximate BTU’s consumed and the operating hours you
can reasonably expect from bulk propane cylinders.

2.  FOR SAFE OPERATION

A.

READ INSTRUCTIONS CAREFULLY:

 Read and adhere to these

instructions. Do not allow anyone who has not read the
instructions to assemble, light, adjust or operate the heater.

   

WARNING

KEEP THE HEATER OUT OF THE REACH OF CHILDREN

B.

PROPANE IS VERY FLAMMABLE:

 In the event of a leak,

propane will accumulate and the possibility of a fire is present.
Propane gas is scented and its strong odor is readily detectable.
Never strike a match or bring any flame or create an electric
spark in an enclosure when you smell propane gas. Ventilate
the area thoroughly, move the heater outside, find and correct
the source of the leak before attempting to light any appliance.
If you are unsure of these instructions evacuate immediately
and call for help.

C.

GAS LEAKAGE:

 If the leak cannot be corrected, do not tamper

with the heater; follow the shut down instructions and return
the heater to the dealer or address given on last page.

   

WARNING

DO NOT USE THIS HEATER ON BULK TANKS OF GREATER
CAPACITY THAN 100 POUNDS LPG

D.

LEAK DETECTION:

 Before each use of the heater check all

fittings and connections with a soap solution to be sure there
are no leaks. Be sure the POL fitting is wrench (7/8”) tightened
into the On-Off valve on the propane cylinder. 

NEVER

NEVER

USE ANY FLAME FOR LEAK TEST.

E.

CONNECTING HEATER TO PROPANE CYLINDER:

 Always

connect the heater to the bulk cylinder in the outdoors or in a
well ventilated area. Use a 7/8” open end wrench. NEVER
connect this heater to a cylinder near an open flame.

F.

USE OF HEATER:

 Always operate the heater with the propane

cylinder in an upright position on a level noncombustible
surface. NEVER place the cylinder on its side when operating
the heater.

G.

ATTEND HEATER:

 Do not leave heater unattended while it is in

operation.

H.

ALWAYS USE A MATCH TO LIGHT HEATER:

 

NEVER

 attempt

to light the heater with a spark lighter.

I.

DO NOT TAMPER:

 Should the heater not perform properly,

such as little or no heat when operating in the “Hi” position, or
for any other reason, DO NOT ATTEMPT TO REPAIR OR TAMPER
with the heater. Any tampering could make the use of the
heater unsafe and dangerous. Return the heater to the dealer
or the address given on last page for repair or replacement.

J.

FOR STORAGE:

 The heater Hi-Med-Lo-Off regulating valve

should always be turned to “Off” when the heater is not in use.
Allow at least 15 minutes for cooling before handling and
storing. Detach propane cylinder from heater before storing.
DO NOT store propane cylinders near open flame or heat.

K.

DO NOT TRANSPORT OR MOVE APPLIANCE WHILE IN

OPERATION OR WHILE HEATER IS ATTACHED. FOLLOW
SHUTDOWN AND STORAGE INSTRUCTIONS TO
TRANSPORT OR MOVE THIS APPLIANCE.

WARNING

Asphyxiation Hazard

• Do not use this heater for heating human living

quarters.

• Do not use in unventilated areas.
• The flow of combustion and ventilation air must not

be obstructed.

• Proper ventilation air must be provided to support

the combustion air requirements of the heater
being used.

• Refer to the specification section of the heater’s

manual, heater dataplate, or contact the factory to
determine combustion air ventilation requirements
of the heater.

• Lack of proper ventilation air will lead to improper

combustion.

• Improper combustion can lead to carbon monoxide

poisoning leading to serious injury or death.

• Symptom of carbon monoxide poisoning can

include headaches dizziness and difficulty in
breathing.

1

Hi

14,000

31

157

1

Med

2,000

36

184

1

Lo

8,000

43

217

2

Hi

28,000

15

78

2

Med

24,000

18

92

2

Lo

16,000

21

108

3

Hi

42,000

10

52

3

Med

36,000

12

61

3

Lo

24,000

14

72

 

Burners

     Valve        BTU Input        Approximate Hours of Operation

 

Operating     Position

            20 Lb. Cylinder     100 Lb. Cylinder

Figure 2

Содержание MH42T

Страница 1: ...rty damage personal injury or loss of life WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appli ance WHAT TO DO IF YOU SMELL GAS Do not try to light appliance Extinguish any open flame Shut off gas to appliance Service must be perf...

Страница 2: ...E OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNER DUST PAR TICLES OR UNKNOWN CHEMICALS WARNING COMBUSTION BY PRODUCTS PRODUCED WHEN USING THIS PRODUCT CONTAIN CARBON MONOXIDE A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM WARNING NOT FOR HOME OR RECREATIONAL VEHICLE USE WARNING YOUR SAFETY IS IMPORTANT TO YOU AN...

Страница 3: ... 1 5 Make sure tank valve is in OFF position clockwise 1 6 Make sure regulator knob is in OFF position by turning knob clockwise to off 1 7 Carefully screw POL nut directly into bulk tank valve finger tight turning counterclockwise then with a 7 8 open end wrench tighten the POL fitting hard 1 8 Always connect the heater to bulk tank in the outdoors or in a well ventilated area NEVER connect heate...

Страница 4: ...cylinder in the outdoors or in a well ventilated area Use a 7 8 open end wrench NEVER connect this heater to a cylinder near an open flame F USE OF HEATER Always operate the heater with the propane cylinder in an upright position on a level noncombustible surface NEVER place the cylinder on its side when operating the heater G ATTEND HEATER Do not leave heater unattended while it is in operation H...

Страница 5: ...lly screw POL nut directly into bulk propane cylinder counterclockwise REMEMBER This is a left hand thread see Figure 1 Make sure the heater is in a vertical upright position and directed away from the collar of the bulk tank Use a 7 8 open end wrench to tighten the POL fitting left hand thread see Fig 1 6 LIGHTING INSTRUCTIONS A Before attempting to light the heater check all fittings and connect...

Страница 6: ...ment Regulator with Soft Nose POL 7 73743 Reflector 8 73742 Wire Guard 9 75607 Metal Ring 10 73938 Collar Mounting Bracket Assembly 11 73658 Hose Assembly Less Regulator 11 Long 12 73213 Replacement Safety Shutoff with Orifice 13 75613 Locking Knob 14 73214 Bolt 20 with Seal Washer 15 73322 Plenum Assembly with Clip Center Only Mr Heater Gas Fired Infra Red Portable Heater Model MH42T Figure 6 Fig...

Страница 7: ...O NOT STORE PROPANE TANK WITHIN 60 FT OF OPEN FLAME OR HEAT E See Figure 6 for spare parts list PROBLEM POSSIBLE CAUSE SOLUTION Burners will not light Propane tank turned off Open tank valve Propane tank empty Get tank filled Heater regulator not turned on Turn valve to medium position Safety Shutoff plunger not depressed Depress S S valve while lighting Air in manifold or hose or propane tank Pur...

Страница 8: ... details concerning the claim Also supply us with the purchase date and the name and address of the dealer from whom you purchased our product The foregoing is the full extent of the responsibility of the Company There are no other warranties express or implied Specifically there is no warranty of fitness for a particular purpose and there is no warranty of merchantability In no event shall the Co...