STXDF TROWEL • SETUP, ADJUSTMENTS AND CALIBRATIONS — REV. #0 (11/05/18) — PAGE 23
PITCH SENSOR CALIBRATION
1. Make sure pitch actuator rod ends are screwed in far
enough for the yoke to lift off the pressure plate when
fully retracted.
2. Verify that pitch actuator rod end jam nuts are tight.
3. Turn machine off for at least 10 seconds and then
restart machine.
4. On the service tool main screen (Figure 23), click the
"Calibration" button.
5. Click the “Pitch Calibration Screen” button in Pitch
Sensors section (Figure 36).
Figure 36. Pitch Sensor Calibration
6. Click “Start Pitch Calibration” button.
7. After verifying that it is safe for the complete machine
to move up and down several inches, click “Safe to
Start” to begin calibration.
8. Once done, record pitch calibration values.
MACHINE SETUP AND CALIBRATION
9. Check that both left and right pitch neutral calibration
points are at least 10.0 mm (Figure 37).
Figure 37. Neutral Calibration Points
10. If a neutral calibration point is not 10.0 mm or more,
then the pitch actuator rod end for that side, left or
right, must be screwed further into the actuator and
pitch recalibrated.
ADJUSTMENT NEEDED
OK