PAGE 12 — STXDF TROWEL • SETUP, ADJUSTMENTS AND CALIBRATIONS — REV. #0 (11/05/18)
GENERAL PROCEDURES
SETUP JUMPER INSTALLATION
NOTICE
These general procedures will be referenced in other
sections throughout the manual.
NOTICE
Machine must be secured prior to installation. Installing
setup jumper will:
• Disable Cold Start
• Increase Engine RPM to Full operating RPM
• Disable Stroke Follower
1. Remove plug (P/N: 42440) from J5 of main harness
(under the seat: above and left of the cup holder).
2. Install Setup Jumper (P/N: 42538 on J5).
REMOVE SETUP JUMPER
(If installed).
1. Remove Setup Jumper (P/N: 42538) from J5 of main
harness.
2. Reinstall Plug (P/N: 42440) on J5 of main harness.
Table 2. Disable and Enable Options
DISABLE
(If Setup Jumper is not
installed)
Cold Start
1.
Open service tool.
2.
Click “machine setup” button on main page.
3.
Click “Cold Start” button under Setup Menu.
4.
Click check box next to Disabled.
5.
Press Download Button.
Stroke Advanced Features
1.
Open service tool.
2.
Click “machine setup” button on main page.
3.
Click “Stroke Cont.” button under Setup Menu.
4.
Click button “Disable Cruise, Ramp, Pwr Mang,Stroke Follower”.
DISABLE
(Regardless of Setup
Jumper)
Fan Control
1.
Open service tool.
2.
Click “Machine Setup” button on main page.
3.
Click “Fan Control” button under Setup Menu.
4.
Click check box next to Disabled.
5.
Press Download Button.
Battery Management
1.
Open service tool.
2.
Click “Machine Setup” button on main page.
3.
Click “Bat. Man.” button under Setup Menu.
4.
Click check box next to Disabled.
5.
Press Download Button.
Thermal Management
1.
Open service tool.
2.
Click "Enable Advanced Screens" on the main page.
3.
Click “Machine Setup” button on main page.
4.
Click “Stroke Cont.” button under Setup Menu.
5.
Click "Thermal Management" under Advanced Functions.
6.
Click check box next to Thermal Management Bypass.
7.
Press Download Button.
Hydraulic Level Faults
1.
Open service tool.
2.
Click “Diagnostics” button on main page.
3.
Click “Sensor Diagnostics” button under input & Output Diagnostics.
4.
Click "Fluid Levels" under Sensor Diagnostics.
5.
Click check box next to Disabled under Parameters.
6.
Press Download Button.