PAGE 14 — STXDF TROWEL • SETUP, ADJUSTMENTS AND CALIBRATIONS — REV. #0 (11/05/18)
INITIAL CHECK AND ADJUSTMENTS
HYDRAULIC OIL CHECK
1. Turn the ignition key to the
ON
position and press the
F3 button
to access the
machine information
screen.
2. Press the
down arrow button
to scroll downward until
HYD LEVEL
(Figure 5) is displayed on the screen.
The hydraulic oil level should be 20–75% when the
oil is cold.
Figure 5. Hydraulic Oil Level Display
3. If the hydraulic oil level is low, raise the lifting bail and
open the main hood of the trowel as shown in Figure 6.
Figure 6. Lifting Bail and Main Hood
LIFTING BAIL
MAIN
HOOD
4. The hydraulic oil reservoir cover will need to be
removed in order to access the hydraulic oil fill cap.
Remove the five bolts securing the cover to the frame
(Figure 7). Set the cover and bolts aside.
Figure 7. Hydraulic Oil Reservoir Cover
Removal
5. Remove the hydraulic oil filler cap (Figure 8).
Figure 8. Hydraulic Oil Filler Cap
6. Add hydraulic oil up to a level midway between the
MIN
and
MAX
lines on the reservoir or 50% as shown on
the digital display when the oil is cold.
DO NOT
overfill.
Use only Parker DuraClean™ ISO 46 hydraulic oil.
Replace the filler cap when finished.
7. Reinstall the hydraulic oil reservoir cover with the five
bolts that were removed earlier.
REMOVE
BOLTS
5 PLACES
CAUTION
Hydraulic oil can get
HOT!
ALWAYS
allow hydraulic oil to cool before
removing the fill cap.
NEVER
remove the fill
cap when the oil is hot or spillage may occur.
HYDRAULIC OIL