![MQ Multiquip Mikasa MVH120 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/mq-multiquip/mikasa-mvh120/mikasa-mvh120_service-manual_1844257026.webp)
5. Checking the vibrator oil (See Fig.35):
In every 100 hours of operation, position the
machine horizontally and remove the vibrator
oil level check plug (use 14mm wrench) to see
oil is up to the port.
In every 300 hours of operation, change the
vibrator oil. Drain oil through level check
plug hole with the machine inclined by
inserting a sleeper or the like under the
opposite side of compaction plate.
Fig.35
Effective
range of oil
※
Lubrication oil to use: Engine oil 10W-30.
Oil Capacities: R60 Series: 0.25 Liter
1
2
0 Series: 0.35 L
150 Series: 0.35 L
! Note:
To prevent dust from entering, clean the port before proceeding with the vibrator oil check.
!Note:
In case any leakage from vibrator should be detected, check vibrator oil frequently.
6. Checking the hydraulic oil (See Fig.36):
a.
Check the hydraulic oil in every 100 hours of operation.
With the handle positioned vertically (stowed position), remove breather plug at the top of
hydraulic hand pump and check the oil for proper level (To OIL LEVEL mark)
Fig36
Hand pump
Plug cap
Breather plug
23