Pendulum shaft (driven)
11
(
MVH-R60
)
4-4 Remove seal cap (27).
4-5 Remove pendulums (19, 20) from each
pendulum shaft (See Fig.4).
4-6 Shift the pendulum (driven shaft side) (4) to
one side of the vibrator case (1) and remove
bearing (2) using the pulley puller, before
removing the pendulum assembly from the
vibrator case (See Fig.5).
4-7 Push out the stop ring (5) and gear (driven
shaft side) to one side and pull it out. If the
gear is hard to remove, use the press rather
than tapping on it with hammer. (See Fig.6.)
4-8 Push the knock pin (12), with your finger or
by using a plastic hammer if it is sticky, which
will allow to pull out piston rod (11) from the
pendulum shaft (See Fig.7).
(
MVH-120 AND 150
)
4-4 Remove seal cap (25).
4-5 Remove pendulum (18) from each pendulum
shaft (See Fig.8).
4-6 With the driven shaft assembly pushed out to
the side opposite to pulley and the bearing (2)
taken out, remove the driven shaft assembly
from the vibrator case (See Fig.8).
4-7 Disassembling the driven shaft:
Remove four mounting bolts (10) and take out
bearing holder (8) (See Fig.9).
4-8 Remove four mounting bolts (44) and driven
gear (31). Tap on and remove parallel pin (12)
before pulling out piston rod(11) from driven
shaft (4) (See Fig.10).
With two contraction stop rings (5) removed,
remove 210
°
cam ring (7) from driven shaft (4)
before removing bearing (9) as well (See
Fig.11).
Pendulums
Fig.4
Pendulum shaft (driven shaft side)
Bearing
Fig.5
Gear Fig.6
Driven shaft
Fig.11
Fig.10
Fig.9
Fig.8
The side opposite to pulley
Fig.7
Knock pin
Piston rod
Pendulum shaft (driven)
Содержание Mikasa MVH120
Страница 13: ...10 ...