MAYCO C-30HDNI PUMP — OPERATION AND PARTS MANUAL — REV. #0 (05/15/03) — PAGE 61
APPENDIX — C-30HDNI RECOMMENDED SHOTCRETE SYSTEM
General recommendations
■
If the site will permit, use steel pipe from the pump
to the pool perimeter. It will reduce line pressures
which is highly recommended.
■
The vibrator on the reducer by the pool improves
pumpability.
■
Turn both air vibrators off whenever the pump is
stopped to prevent separation of mix.
■
The air vibrators are low consumption (4.2 scfm).
■
Leave the air on at the nozzle when the pump is
stopped to prevent clogging of air the hoses in the
air insert.
■
Use item #11 (steel elbow) at the edge of the pool
to prevent collapse of the rubber hose, which can
cause blockage.
RECOMMENDED SHOTCRETE SYSTEM
NO.
PART NO.
PART NAME
QTY.
REMARKS
1
EM28904 ......... 3" “B” COUPLING
2
EM23946 ......... 3"-90° ELBOW
3
EM28903 ......... 2 1/2" S/J COUPLING
4
EM28005DD .... 3"X 2 1/2 REDUCER
5
EM28061 ......... 2 1/2"X 10FT. PIPE
6
EM24849 ......... 2 1/2"X 50FT. HOSE
7
EM28001DD .... 2 1/2"X 2" REDUCER
8
EM23815D ....... 2 1/2"X 2" REDUCER
W/AIR VIBRATOR
9
EM28902 ......... 2" S/J COUPLING
10
EM23101 ......... AIR VIBRATOR
11
EM28131 ......... 2"X 2 ELBOW
12
EM24841 ......... 2"X 25 FT. HOSE
13
EM23808D ....... NOZZLE ASSEMBLY
14
EM23806 ......... 1 3/8" NOZZLE TIP
15
EM23807 ......... 1 1/4" NOZZLE TIP
Go to Discount-Equipment.com