MAYCO C-30HDNI PUMP — OPERATION AND PARTS MANUAL — REV. #0 (05/15/03) — PAGE 27
C-30HDNI PUMP — OPERATING INFORMATION
15. New Pumps – All new pumps are “
water pressure tested ”
at the factory before shipment. This procedure permits a thor-
ough inspection of the entire drive system and valving under
simulated full load conditions.
The pump owner can do the same by attaching an adaptor
couple to the end of the discharge cone; e.g., the use of a
standard 2” pipe cap with a 3/8” hole drilled in the center,
screwed on to the end of the hinged cone or reducer at the
pump.
Fill the hopper with water after making sure that all sand and
rock have been removed from the manifold. Operate the
pump at full throttle and the 3/8” diameter hole restriction will
create sufficient back-pressure to make a thorough inspec-
tion of all moving parts.