SAFETY WARNING

Date: 10/16/19
To: 

Electric Walk-Behind Trowel Owners

From: 

Multiquip Product Department

Subject:  Only Operating J36E2/J42E on 230 VAC

Dear Multiquip Customer,
Our records indicate you purchased an MQ Whiteman power trowel equipped with a 2.0 hp electric motor 

rated for 115-volt or 230-volt operation. This type of trowel is identified by the following model numbers: J42E 

and J36E2.
These trowels were originally manufactured to operate at 115 volts with the optional capacity to operate at 

230 volts.
One of the safety features of the trowel is the Operator Presence ON/OFF Lever Switch. When the lever is 

released, power to the electric motor will be interrupted.
We have learned that the electric switch that enables power interruption is underrated for the electrical current 

required for safe operation at 115 volts. In rare circumstances, electrical contacts in the switch may fail, preventing 

the Operator Presence ON/OFF Lever Switch from operating as intended. Failure of the switch could result in 

a runaway trowel and SERIOUS INJURY and/or property damage.
Multiquip is unaware of any reports of electric switch failure resulting in the failure of the Operator Presence 

ON/OFF Lever Switch. However, we believe it is necessary to bring this to your attention as a safety precaution.
If you own any of these models listed above, use the trowel only in its 230-volt configuration and for 230-volt 

operation only. 

DO NOT CONTINUE OPERATING THE TROWEL USING 115-VOLT POWER.

 Conversion 

(rewiring) to 230-volt operation should be done only by a qualified technician or a Multiquip service center.

Is a replacement micro-switch available that permits operation using 115-volt power?

No. At this time a replacement switch is not available.

What if I have sold the trowel?

Please forward this Notice or a color copy of this Notice to, or provide us with contact information for, the new 

owner or retail purchaser.

How do I rewire the motor to 230 volts?

The conversion should only be done by a qualified technician or equipment service center. If you need 

assistance locating a service center please call the Multiquip warranty department at 800-421-1244 or email 

us at [email protected].

Is this campaign covered under warranty?

Yes. If the original product warranty period has expired, Multiquip will extend the new product limited warranty 

to cover conversion costs in accordance with this campaign. See Warranty Information below.

Содержание J36E2

Страница 1: ...UAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES To find the latest revision of this publication visit our website at www multiquip com MODEL J36E2 WALK BEHIND TROWEL 2 HP ELECTRIC MOTOR S N LE0118039 AND BELOW Revision 2 01 31 18 PN 23814 ...

Страница 2: ...LE0118039 and below it will need to be rewired for 230 volt operation Please see the attached Safety Warning and Service Bulletin for details NOTICE For current operation and or parts information for the J36E2 Walk Behind Trowel go to www multiquip com and refer to the operation and parts manuals for the J36E2 S N LE0118040 and above ...

Страница 3: ...ectric switch failure resulting in the failure of the Operator Presence ON OFF Lever Switch However we believe it is necessary to bring this to your attention as a safety precaution If you own any of these models listed above use the trowel only in its 230 volt configuration and for 230 volt operation only DO NOT CONTINUE OPERATING THE TROWEL USING 115 VOLT POWER Conversion rewiring to 230 volt op...

Страница 4: ...llowance 1 0 hour total flat rate for rewire of unit from 115 VAC to 230 VAC Your prompt attention to this matter is appreciated If you have questions please contact the MultiquipTechnical Support Department at 800 478 1244 or techsupport multiquip com We appreciate your business and apologize for any inconvenience this creates Our goal remains to supply you with top quality equipment and superior...

Страница 5: ...ator Presence ON OFF Lever Switch from operating as intended Failure of the switch could result in a runaway trowel and SERIOUS INJURY and or property damage Solution If you own any of these models listed above use the trowel only in its 230 volt configuration and for 230 volt operation only DO NOT CONTINUE OPERATINGTHETROWEL USING 115 VOLT POWER Conversion rewiring to 230 volt operation should be...

Страница 6: ... the motor is turned OFF EXISTING PLUG REMOVAL 1 Remove the two screws securing the switch box cover to the front of the main switch box Figure 2 Keep the screws for later Figure 2 Remove Main Switch Box Cover 2 Open the main switch box and disconnect the three power cable wires Figure 3 MAIN SWITCH BOX COVER REMOVE 2 SCREWS Figure 3 Disconnect Power Cable Wires 3 Remove the two small screws Figur...

Страница 7: ...y wires and crimp See Figure 5 0 25 230V PIGTAIL ASSEMBLY P N 30718 RING TERMINAL P N 30096 3 Connect the three pigtail assembly wires inside the main switch box as shown in Figure 6 Figure 6 Install New Power Cable 4 Finish installing the 230V pigtail assembly P N 30718 by inserting the push on liquid tight connector into the open hole on the main switch box Make sure the connector is fully seate...

Страница 8: ...Connect the red and yellow wires from the motor with the white wire from the handle using a crimp sleeve P N 19687 and splice cap insulator P N 19688 See Figure 7 3 Connect the yellow black wire from the motor with the black wire from the handle using a pre insulated crimp 16 12 AWG wire nut P N 34938 See Figure 7 4 Use the remaining pre insulated crimp 16 12 AWG wire nut P N 34938 to cap off the ...

Страница 9: ...ELECTRIC WALK BEHINDTROWEL SERVICE BULLETINTR20190823 REV 1 10 16 19 PAGE 5 NOTES ...

Страница 10: ...C Multiquip Inc and the MQ logo are registered trademarks of Multiquip Inc and may not be used reproduced or altered without written permission All other trademarks are the property of their respective owners and used with permission The information and specifications included in this publication were in effect at the time of approval for printing Illustrations descriptions references and technica...

Отзывы: