15
02
Maximum charging current:
To configure total charging
current for solar and utility
chargers.
(Max. charging current =
utility charging c
solar charging current)
60A (default)
3KW model setting range is from
10A to 120A and increment of
each click is 10A.
5KW model setting range is from
10A to 140A and increment of
each click is 10A.
05
Battery type
AGM (default)
Flooded
User-Defined
If “User-Defined” is selected,
battery charge voltage and low
DC cut-off voltage can be set up
in program 26, 27 and 29.
Pylontech battery (only for
5KW)
If selected, programs of 02, 26,
27 and 29 will be automatically
set up. No need for further
setting.
06
Auto restart when overload
occurs
Restart disable (default)
Restart enable
07
Auto restart when over
temperature occurs
Restart disable (default)
Restart enable
09
Output frequency
50Hz (default)
60Hz