MOZELT T4002 Скачать руководство пользователя страница 9

4.3 

Operating instructions

When working with the load lifting magnet, the pertinent 

industrial safety and accident prevention regulations are 

to be observed.

In  addition,  lifting  magnet  operation  may  only  be 

started, if the operator knows the „Safety Regulations 

Magnet Operation“ (see Table of Contents).

Before start-up of the power supply T 4002, the operator 

should  ensure  that  the  220V  cable  system  is  in  an 

optically  perfect  condition.  Plugs  and  plug  connectors 

are to be examined for tightness of fit, the anchoring 

device of the magnet connecting cable is to be examined 

for perfect function. 

The V-belt tension with belt drives is to be examined and, 

if necessary, the belts are to be retightened according to 

regulation.

Unless otherwise expressly stated, the diesel engine 

of the mobile excavator is to be brought up to full 

revolutions. The generator then runs within its operating 

range. The yellow LED „

Ready

“ automatically appears on 

the multi-function display MFA I in the operator‘s cab. 

Switching  the  power  supply  and/or  the  load  lifting 

magnet  on  and  off  is  usually  accomplished  with  a 

switch located in the handle. Depending on the type of 

device, this must be energized with a separate switch 

in the control console of the mobile excavator. For this 

purpose also see the notes in the manual for the mobile 

excavator. 

If the switching-on command is given, then the generator 

T  4002  connects  the  voltage  contactless  through  to 

the  load  lifting  magnet.  If  the  command  is  given  to 

switch off, then the generator automatically leads to its 

demagnetization. 

During  the  process  of  demagnetizing,  whereby  the 

magnet  releases  its  load  (approx.  1  sec),  no  renewed 

switching-on command can be given.

Switching-on of the installation is only possible, if a load 

lifting magnet is attached to the system.

Switching on the magnet: 

Operate the button in the control lever 1 x. 

In  addition  to  the  yellow  LED  „

Ready

“,  the  green  LED 

Power on

“ lights up in the multi-function display.

Switching off the magnet: 

Operate the same button in the control lever again only 

1 x. 

The already illuminated green LED „

Power on

“ now goes 

out and a red LED with „

Power off

“ lights up. After the 

load has been dropped, this goes out automatically. 

The  permanently  illuminated  LED  „

Ready

“  during  the 

shifting processes indicates that a renewed procedure is 

now possible and that the power can be switched on. 

Breakdowns  are  indicated  by  illuminated  red  LEDs. 

The meaning and elimination of such disturbances are 

explained using figurative illustrations and texts under 

-  Breakdown  indicators  on  the  MFA  -  (see  4.7  page 

12/13).

Operation with load lifting magnet:

 

 

First place the magnet on the 

 

 

material and then switch it on. 

 

 

Swivel the magnet back in a 

 

 

switched-off state.

Fig. 9  | Touch down of the switched-off magnet on the material 

First ‘touch down’ 

of the magnet, then 

switch it on !

www.mozelt.com

CAUTION

Englisch

MOZELT GmbH & Co. KG

Load lifting magnet devices

Technical Manual:

 Electrical Power Supply T4002

Copyright:  

MOZELT GmbH & Co. KG, D-47269 Duisburg 

 

 

Edition:    May 2012 

 

-9- 

Содержание T4002

Страница 1: ...g magnet devices Technical Manual Electrical Power Supply System T4002 Please observe the following safety information and recommendations before start up Copyright MOZELT GmbH Co KG D 47269 Duisburg Edition Mai 2012 www mozelt com ...

Страница 2: ...ing and protection devices The manufacturer s documentation is to be observed After separating the generators from the drive unit live components and line connections must not be touched when the generator spindle is running due to the voltage All covers are to be kept closed during operation 4 Operation Installations into which the generators are built must be equipped if necessary with additiona...

Страница 3: ...Operating instructions 9 4 4 Overview multi function display MFA 10 4 5 Structural design of current supply 10 4 6 Operational indicators MFA 11 4 7 Fault indicators MFA 12 All passages in the manual which are marked with the symbol Warning contain information which is important to avoid danger WARNING All passages in the manual which are marked with the symbol Caution contain information which is...

Страница 4: ... the supply voltage passive protection for individuals 1 Technical description 1 1 Range of applications The MOZELT power supply system with synchronous generator is designed to supply and activate load lifting magnets on mobile excavators At present it is available with the output sizes 13 20 and 30 kW Due to the duty rating of 100 ED the generators are the optimal solution for loading and handli...

Страница 5: ...cal cable connections The electrical cable connections as well as the plug connections plugs coupler are matched for the respective loads of the generators The highest demands are placed on functionality and safety If necessary please use only original spare parts 2 2 3 Generator drives Depending on the version of the mobile excavator the generator is powered mechanically or hydraulically Both var...

Страница 6: ...issipated The ventilator screen must always be kept free in order to ensure an adequate supply of fresh air All heat sources must be considered when determining the ambient temperature so that the temperature does not rise above the permissible maximum value for the generator 3 2 Connections 1 Protective conductor connection Magnet connection Connection for control cable to the MFA 1 2 3 Fig 3 Con...

Страница 7: ...erator 20 kW DPE 0815 Fig 5 Generator 30 kW DPE 0920 Spline shaft W 30 x 2 x 30 x 14 x 9g DIN 5480 www mozelt com Englisch MOZELT GmbH Co KG Load lifting magnet devices Technical Manual Electrical Power Supply T4002 Copyright MOZELT GmbH Co KG D 47269 Duisburg Edition May 2012 7 ...

Страница 8: ...fted material after it is switched off if there is cable damage or a short circuit in the magnet feed cable This can lead to dangerous situations in the working vicinity for example if falling material causes other objects to be hurled up by lever force Furthermore it is not excluded that pieces of scrap iron may separate from the magnet during a swiveling procedure if these are located at the low...

Страница 9: ...less through to the load lifting magnet If the command is given to switch off then the generator automatically leads to its demagnetization During the process of demagnetizing whereby the magnet releases its load approx 1 sec no renewed switching on command can be given Switching on of the installation is only possible if a load lifting magnet is attached to the system Switching on the magnet Oper...

Страница 10: ...enerator T4002 Multi function display MFA MFD I Operating switch on the control lever Switch cable Control cable Magnet cable 220 V Connector Magnet connecting cable Load lifting magnet The essential components are 1 5 6 Function and breakdown indicators see 4 6 and 4 7 page 11 13 Relative on time of the magnetic plate in www mozelt com Englisch MOZELT GmbH Co KG Load lifting magnet devices Techni...

Страница 11: ...n command given via operating switch the magnet lifts Fig 13 MFA indicates an activated magnet 2 Display LED 1 yellow Ready LED 3 red Power off Note Magnet releases the material 1 After switching off command given via operating switch magnet releases load Fig 14 MFA indicates the release of the material 3 www mozelt com Englisch MOZELT GmbH Co KG Load lifting magnet devices Technical Manual Electr...

Страница 12: ...ff command given via operating switch LEDs flash 1 Fig 17 MFA indicates short circuit Display Possible cause Display Possible cause Cable break in the 220 V circuit Magnet attached wrongly or not attached Cable or connector defective Magnet defective Display Posible cause LED 1 5 flashing Short circuit in the cable system 220 V Full earth fault of the magnet Magnet too much power for electrical su...

Страница 13: ...ssible cause The generator is running too fast Display Possible cause Note Turn off the engine immediately and have the speed checked in order to prevent damage to the generator LED 1 yellow Ready LED 5 red R P M not o k possibly also flashing The generator is running too slow Normal magnet operation is only possible to a limited extent lower performance is to be expected LED 5 permanent speed 220...

Отзывы: