16
Firmware Upgrade
Updating the firmware of Slypod E should be done in the charging state. When in
charging state, turn on the device, connect it to the App, enter the operation interface
and start the firmware upgrade. The device must be restarted after the firmware
upgrade succeeds. If the upgrade fails, the process needs to be repeated until the
upgrade succeeds.
Color Definition
Charging
Solid red
Charging completed
Solid blue
Power on
Solid green
Under-voltage alarm
Solid orange
Low voltage alarm
Blinking red + automatic reset & shutdown
(unable to power on when pressing the power
button)
Start/stop running switch
Blinking green for 1s
Calibration status
Blinking white
Testing/operating modes switch
Blinking blue for 1s
Charging
Uncover the rubber sleeve over the charging port, the Type-C interface is inside. The
Slypod E can be charged by mobile phone charger, mobile power bank, etc. It will
automatically stop charging when the battery is full, please disconnect the charger then
(It is recommended to use the original charging cable provided in the package)
Calibration
Calibration is needed when there is abnormality with the device. There are two ways to
calibrate the Slypod E: Click all three buttons (power, +, -) at the same time. Enter the
operation interface to start calibration in the App. Please subscribe Gudsen MOZA
official YouTube channel for the latest tutorials.