- 13 -
Grounding the Moxa VPort 364
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from the
ground screw to the grounding surface prior to connecting devices.
ATTENTION
This product is intended to be mounted to a well-grounded
mounting surface, such as a metal panel.
Wiring the Redundant Power Inputs
The VPort 364 has two sets of power input, power input 1 and power input
2, which are located
on the two 5-pin terminal block connectors. Top and
front views of the terminal block connectors are shown here.
STEP 1:
Insert the negative/positive DC or
AC wires into the V-/V+ terminals.
STEP 2:
To keep the DC or AC wires from
pulling loose, use a small flat-blade
screwdriver to tighten the wire-clamp screws
on the front of the terminal block connector.
STEP 3:
Insert the plastic terminal block
connector prongs into the terminal block
receptor, which is located on the VPort 364’s
top panel.
ATTENTION
The power for this product is intended to be supplied by a Listed
Power Unit, with output marked LPS, and rated to deliver 12 to 32
VDC at a maximum of 510 mA (at 12VDC), or 18 to 30 VAC at a
maximum of 512 mA (at 18VAC). The maximum power
consumption is 7.5W.
ATTENTION
Before connecting the VPort to the AC/DC power inputs, make
sure the DC power source voltage is stable.