Connecting the Relay Outputs
Each TN-5516/5518 switch has two sets of relay outputs—relay output 1
and relay output 2.The M12 A-coded 5-pin male connector on the
TN-5516/5518 front panel is used for the two relay outputs. Use a power
cord with an M12 A-coded 5-pin female connector to connect the relay
contacts. You can purchase an M12 power cable from Moxa; the model
number is CBL-M12 (FF5P)/OPEN-100 IP67.
Pinouts for the relay output port on TN-5516/5518.
N.C.: Not connected
FAULT:
The two sets of relay contacts of the M12 A-coded 5-pin male connector
are used to detect user-configured events. The two wires attached to the
fault contacts form an open circuit when a user-configured ev nt is
triggered. If a user-configured event does not occur, the fault circuit
cting the Data Lines
10/100BaseT(X) Ethernet Port Connection
All TN-5516/5518 models have 16 10/100BaseT(X) Ethernet ports (4-pin
shielded M12 connector with D coding). The 10/100TX ports located on
the TN-5516/5518 front panel are used to connect to Ethernet-enabled
devices. Most users configure these ports for Auto MDI/MDI-X mode, in
which case the port’s pinouts are adjusted automatically depending on
the type of Ethernet cable used (straight-through or cross-ove ), and the
type of device (NIC-type or HUB/Switch-type) connected to the port.
X
straight-through and cross-over Ethernet cables.
Pinouts for the 10/100BaseT(X) Ports on the
TN-5516/5518.
e
remains closed.
Conne
r
In what follows, we give pinouts for both MDI (NIC-type) ports and MDI-
(HUB/Switch-type) ports. We also give cable wiring diagrams for
Housing: shield
- 13 -