PT-7728 User’s Manual
Featured Functions
3-15
These parameters are configured on the SNMP page. A more detailed explanation of each
parameter is given below the figure.
SNMP Read/Write Settings
SNMP Versions
Setting
Description
Factory Default
V1, V2c, V3, or
V1, V2c, or
V3 only
This specifies the SNMP protocol version
used to manage the switch.
V1, V2c
V1, V2c Read Community
Setting
Description
Factory Default
Max. 30 characters
This specifies the community string to
authenticate the SNMP agent for read-only
access. The SNMP agent will access all
objects with read-only permissions using
this community string.
Public
V1, V2c Write/Read Community
Setting
Description
Factory Default
Max. 30 characters
This specifies the community string to
authenticate the SNMP agent for
read/write access. The SNMP server will
access all objects with read/write
permissions using this community string
.
Private
For SNMP V3, there are two levels of privilege for different accounts to access the PT-7728.
Admin
privilege provides access and authorization to read and write the MIB file.
User
privilege
allows reading of the MIB file only.