![Moxa Technologies NPort 5100 Series Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/moxa-technologies/nport-5100-series/nport-5100-series_user-manual_1842541034.webp)
NPort 5100 Series User’s Manual
Web Console Configuration
5-9
Stop bits
Setting
Factory Default
Necessity
1, 1.5, 2
1
Required
Stop bits will be set to 1.5 when Data bits is set to 5 bits.
Parity
Setting
Factory Default
Necessity
None, Even, Odd, Space, Mark
None
Required
Flow control
Setting
Factory Default
Necessity
None, RTS/CTS, DTR/DSR, Xon/Xoff
RTS/CTS
Required
FIFO
Setting
Factory Default
Necessity
Enable, Disable
Enable
Required
NPort 5100’s serial ports provide a 16-byte FIFO both in the Tx and Rx directions. To prevent
data loss during communication, disable the FIFO setting when your serial device does not have a
FIFO.
Interface
Setting
Factory Default
Necessity
RS-232/422/485 only
RS-232/422/485 only
Required
Operating Settings
Click
Operating Settings
, located under
Main Menu
, to display the operating settings for both of
NPort 5100’s serial ports.