Moxa Technologies MDS-G4000 Series Скачать руководство пользователя страница 18

- 18 - 

 

PWR-HV-P48/PWR-LV-P48 

LED 

Color  State  Description 

EPS (External 

Power Supply)  Amber 

On 

External power is being supplied to 

the module's EPS input. 

Off 

No external power supply for PoE. 

PWR 

Amber 

On 

Power is being supplied to the 

module's power input. 

Off 

Power is not being supplied to the 

module's power input. 

PWR-HV-NP/PWR-LV-NP 

LED 

Color  State  Description 

PWR 

Amber 

On 

Power is being supplied to the 

module's power input. 

Off 

Power is not being supplied to the 

module's power input. 

Specifications 

Interface 

Gigabit Ethernet  4-ports 10/100/1000BaseT(X) 

Console Port 

RS-232 console with an RJ45 interface 

LED Indicators  PWR, EPS, STATE, SYNC, FAULT, MSTR/HEAD, 

CPLR/TAIL 

Relay Output 

2 A @ 30 VDC (for Hazardous Location certified 

models, the current carrying capacity is 1 A @ 30 

VDC.) 

Power Requirements 

Input Voltage 

PWR-HV-P48:  

110/220 VDC, 110 VAC, 60 Hz, 220 VAC, 50 Hz,  

PoE: 48 VDC 

PWR-LV-P48 (certified for Hazardous Location 

use):  

24/48 VDC 

PoE: 48 VDC 

PWR-HV-NP:  

110/220 VDC, 110 VAC, 60 Hz, 220 VAC, 50 Hz 

PWR-LV-NP: 

24/48 VDC 

Operating 

Voltage 

PWR-HV-P48:  

88 to 300 VDC, 90 to 264 VAC, 47 to 63 Hz, PoE: 46 

to 57 VDC 

PWR-LV-P48: 

18 to 72 VDC (24 to 48 VDC for 

Hazardous Location), PoE: 46 to 57 VDC (48 VDC for 

Hazardous Location) 

PWR-HV-NP

88 to 300 VDC, 90 to 264 VAC, 47 to 63 Hz 

PWR-LV-NP

:18 to 72 VDC

 

Содержание MDS-G4000 Series

Страница 1: ... N 1802040000005 1802040000005 MDS G4000 MDS G4000 L3 Series Quick Installation Guide Version 1 3 August 2022 Technical Support Contact Information www moxa com support 2022 Moxa Inc All rights reserved ...

Страница 2: ...1 MDS G4020 and MDS G4020 L3 x 2 MDS G4028 and MDS G4028 L3 x 2 Quick installation guide printed Substance Disclosure Table Product Certificate of Quality Inspection Simplified Chinese Product Notices Simplified Chinese Warranty card NOTE You can find information and software downloads on the relevant product pages located on Moxa s website www moxa com Default Settings IP address 192 168 127 253 ...

Страница 3: ...ule slot 6 For MDS G4028 MDS G4028 L3 11 Ethernet module slot 7 For MDS G4028 MDS G4028 L3 12 External power supply input for PoE 13 Redundant power module slot 1 14 Redundant power module slot 2 15 RS232 console port with RJ45 interface 16 Reset button Pin hole 0 9 mm 17 Relay output and Digital Input port 18 Relay output 19 Power input 20 Grounding screw Dimensions MDS G4012 and MDS G4012 L3 Ser...

Страница 4: ...ansceivers LM 7000H 4GTX LM 7000H 4GSFP LM 7000H 4GPoE LM 7000H 4TX LM 7000H 4PoE Power Modules Hardware Rev 2 1 0 and above NOTE The PWR LV P48 power module is certified for Hazardous Location use PWR HV P48 PWR LV P48 PWR HV NP PWR LV NP DIN rail Dimensions and Instructions NOTE The DIN rail kit is certified for Hazardous Location usage MDS G4012 and MDS G4012 L3 Series ...

Страница 5: ...e DIN rail must use the TS35 15 mm specification Wall mounting Dimensions and Instructions Optional WK 112 01 NOTE The wall mount kit is certified for Hazardous Location usage Mounting the switch to a wall requires four screws The heads of the screws should be between 6 0 to 9 0 mm in diameter and the diameter of screw thread should be between 3 5 to 4 mm as shown in the figure on the right Use th...

Страница 6: ...DS G4028 or MDS G4028 L3 products 1 Assemble the right and left part of the kit indicated with No 1 in the diagram with four screws each 2 Assemble the part of the rack kit indicated with No 2 in the diagram with eight screws in order to combine two MDS G4028 or MDS G4028 L3 products Rack Mount Top View ...

Страница 7: ...evice 2 Required Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised NOTE The optimal keep out zone is 50 mm for the top bottom left and right side of the device 3 Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mec...

Страница 8: ...7000H non PoE modules Any power module LM 7000H PoE modules PWR HV P48 PWR LV P48 only NOTE The PWR LV P48 power module is certified for Hazardous Location use PWR HV NP one 110 220 VAC VDC 90 to 264 VAC 88 to 300 VDC power input PWR LV NP one 24 48 VDC 18 to 72 VDC power input For the PWR HV P48 the 110 220 VAC VDC power supplies provide power to the switch Separate 48 VDC power supplies are requ...

Страница 9: ... Power Terminal Blocks The connection for power input and PoE external power supply is on the power modules PWR HV P48 PWR HV NP 1 Insert the neutral line L N Ground AC wires into the terminals 2 Insert the terminal block connector into the terminal block receptor PWR LV P48 PWR LV NP 1 Remove 8 to 9 mm of the DC wires protective cover 2 Use a tool to push the spring mechanism inwards to open it 3...

Страница 10: ...ican Wire Gauge 16 1 31 mm2 and the corresponding pin type cable terminals The rated temperature of wiring should be at least 105 C NOTE When two power units are installed on the switch both power units will be activated simultaneously which will enable power redundancy NOTE The reverse power input connection will not activate the device or PoE input In addition the PoE will only activate when the...

Страница 11: ...DC Digital Input 1 digital output with the same ground but electrically isolated from the electronics 13 to 30 V for state 1 30 to 1 V for state 0 Max input current 8 mA Wiring the Digital Input Output NOTE When wiring the digital input we suggest using the cable type AWG American Wire Gauge 16 24 1 31 0 205 mm2 and the corresponding pin type cable terminals The rated temperature of wiring should ...

Страница 12: ... 4 kgf cm 0 4 Nm Installing and Removing the Power Modules The power supply units are hot swappable when both power modules are installed You have the option to mount or remove the power supply units while the device is operating To install a power module 1 Insert the power unit straight into the slot 2 Fasten the unit to the device by tightening the 2 screws The tightening torque is 3 5 kgf cm 0 ...

Страница 13: ...red in the future Pin Description 1 VCC 5V 2 D Data 3 D Data 4 GND Ground The Reset Button Diameter 0 9 mm The reset button can perform two functions One is to reset the switch to factory default settings and the other is to reboot the switch if the button has been depressed and release immediately Reset to Factory Default Settings Depress the Reset button for five seconds to load the factory defa...

Страница 14: ...and the Turbo Ring Turbo Chain is broken Off When the switch is not the Master Head of this Turbo Ring Turbo Chain C T CPRL TAIL Green On 1 When the switch enables the coupling function to form a back up path or 2 When the switch is the tail of Turbo Chain Blinking This is the switch that enables Turbo Chain but the Turbo Chain function is not working Off When the switch disables the coupling or t...

Страница 15: ...to initialize 2 A module designed for a different model was inserted Copper 10 100 1000Mbps Green On When the port is active and links on 1 000 Mbps Blinking When the port s data is being transmitted at 1 000 Mbps Off When the port is inactive or link down Amber On When the port is active and links on 10 100 Mbps Blinking When the port s data is being transmitted at 10 100 Mbps ...

Страница 16: ...nsmitted at 10 Mbps Off When the port is inactive or link down Copper 10 100 1000Mbps Green On When the port is active and links on 1 000 Mbps Blinking When the port s data is being transmitted at 1 000 Mbps Off When the port is inactive or link down Amber On When the port is active and links on 10 100 Mbps Blinking When the port s data is being transmitted at 10 100 Mbps Off When the port is inac...

Страница 17: ...g When the port s data is being transmitted at 10 Mbps Off When the port is inactive or link down Copper 10 100 1000Mbps Green On When the port is active and links on 1 000 Mbps Blinking When the port s data is being transmitted at 1 000 Mbps Off When the port is inactive or link down Amber On When the port is active and links on 10 100Mbps Blinking When the port s data is being transmitted at 10 ...

Страница 18: ...0 100 1000BaseT X Console Port RS 232 console with an RJ45 interface LED Indicators PWR EPS STATE SYNC FAULT MSTR HEAD CPLR TAIL Relay Output 2 A 30 VDC for Hazardous Location certified models the current carrying capacity is 1 A 30 VDC Power Requirements Input Voltage PWR HV P48 110 220 VDC 110 VAC 60 Hz 220 VAC 50 Hz PoE 48 VDC PWR LV P48 certified for Hazardous Location use 24 48 VDC PoE 48 VDC...

Страница 19: ... ms Maximum PoE Power Output per Port 36 W 15 4 W certified for Hazardous Location use Total PoE Power Budget Max 360 W with one power supply for total PD consumption at 48 VDC input for PoE systems Max 360 W with one power supply for total PD consumption at 53 57 VDC input for PoE systems Max 720 W with two power supplies for total PD consumption at 48 VDC input for PoE systems Max 720 W two powe...

Страница 20: ... MDS G4028 MDS G4028 L3 Wide Temperature Models 40 to 75 C 40 to 167 F MDS G4012 T MDS G4012 L3 T MDS G4020 T MDS G4020 L3 T MDS G4028 T MDS G4028 L3 T Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Standards and Certifications Safety EN 62368 1 UL 62368 1 IEC 62368 1 EMC EN 55035 55032 EMI CISPR 32 FCC Part 15B Class A EMS IEC 61000 4 2 ESD Contact 8 k...

Страница 21: ...eSFP port with LC connector for 10 km transmission TX 1550 nm RX 1310 nm 0 to 60 C operating temperature SFP 1G10BLC T WDM type BiDi SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission TX 1550 nm RX 1310 nm 40 to 85 C operating temperature SFP 1G20ALC WDM type BiDi SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission TX 1310 nm RX 1550 nm 0 to 60 C op...

Страница 22: ...LXLC SFP module with 1 1000BaseLX port with LC connector for 10 km transmission 0 to 60 C operating temperature SFP 1GLXLC T SFP module with 1 1000BaseLX port with LC connector for 10 km transmission 40 to 85 C operating temperature SFP 1GLHLC SFP module with 1 1000BaseLH port with LC connector for 30 km transmission 0 to 60 C operating temperature SFP 1GLHLC T SFP module with 1 1000BaseLH port wi...

Страница 23: ...y Special Conditions of Use The equipment shall only be used in an area of at least pollution degree 2 as defined in EN 60664 1 The equipment shall be installed in an enclosure that provides a degree of protection not less than IP 54 in accordance with EN 60079 0 and accessible only by the use of a tool Transient protection device with capability of voltage clamping rating less than 119Vdc shall b...

Страница 24: ...4 W per port Conductors suitable for rated cable temperature 105 C Hazardous Location EN IEC 60079 0 2018 EN IEC 60079 7 2015 A1 2018 EN IEC 60079 15 2019 Class I Division 2 Groups A B C and D Address of manufacturer No 1111 Heping Rd Bade Dist Taoyuan City 334004 Taiwan CID2 Temp Code T3B ATEX Temp Code 165 C T3 Certification Number UL 20 ATEX 2415X Protection type code Ex ec nC IIC 165 C T3 Gc W...

Отзывы: